The Influence of Holding Device Anchor Parameters on the Holding Force Magnitude, Of an Integrated Linear Electromagnetic Motor.

Autor: Ugarov, Genady G., Moshkin, Vladimir Iv., Massad, Amer Kh.
Předmět:
Zdroj: Asian Journal of Engineering, Sciences & Technology (AJEST); Sep2013, Vol. 3 Issue 2, p84-88, 5p
Abstrakt: This paper investigates the influence of the design parameters of the upper ferromagnetic shunt, namely the value of the holding area SH , that creates a holding force FH, equal to that in breakaway stage in magnitude of this holding force at the breakaway stage. The design of an integrated circuit and the equivalent magnetic circuit of the integrated LEMM on breakaway stage was built, mathematical models of system were laid out. The most acceptable range of these ranges of magnitude of holding area is S*H̥ 0.2...0.4, and this happens when Φ*ush = 0.2...0.4 The resulting holding force will vary in range of (0.05 ... 0.15) to (0.2 ... 0.55). [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index