Measurement of tumor blood flow in head and neck squamous cell carcinoma by pseudo-continuous arterial spin labeling: Comparison with dynamic contrast-enhanced MRI.

Autor: Fujima, Noriyuki, Kudo, Kohsuke, Tsukahara, Akiko, Yoshida, Daisuke, Sakashita, Tomohiro, Homma, Akihiro, Tha, Khin Khin, Shirato, Hiroki
Zdroj: Journal of Magnetic Resonance Imaging; Apr2015, Vol. 41 Issue 4, p983-991, 9p
Abstrakt: Purpose To investigate the feasibility of tumor blood flow (TBF) measurement in head and neck squamous cell carcinoma (HNSCC) using pseudo-continuous arterial spin labeling (pCASL) in a comparison with dynamic contrast-enhanced (DCE) perfusion. Materials and Methods We prospectively scanned 18 patients with HNSCC using 3T magnetic resonance imaging (MRI) with both pCASL and DCE perfusion. Quantitative TBF value in the whole-tumor region of interest (ROI), and regional TBF in the ROIs of the central and peripheral areas in the tumor were respectively measured. Relative TBF value in the whole-tumor ROI was also calculated. We determined the correlation and agreement between each measured TBF by pCASL and DCE perfusion using Pearson's correlation coefficients, intraclass correlation coefficients (ICC), and Bland-Altman analysis. Results In the whole-tumor ROIs, significant correlation was observed between the absolute TBF values ( r = 0.72, P < 0.01), with an ICC of 0.72; moreover, higher correlation was observed in the relative TBF ( r = 0.79). The correlation was higher in the peripheral ROI ( r = 0.70) than the central ROI ( r = 0.65), with an ICC of 0.62 and 0.54, respectively. Bland-Altman plots revealed the underestimation of TBF by pCASL in central ROIs. Conclusion TBF measurement by pCASL was feasible in patients with HNSCC. J. Magn. Reson. Imaging 2015;41:983-991. © 2014 Wiley Periodicals, Inc. [ABSTRACT FROM AUTHOR]
Databáze: Complementary Index