Pema PJ; Department of Radiology, Ohio State University Medical Center, Columbus, USA., Horak HA, Wyatt RH |
Jazyk: |
angličtina |
Zdroj: |
AJNR. American journal of neuroradiology [AJNR Am J Neuroradiol] 1998 May; Vol. 19 (5), pp. 894-6. |
Abstrakt: |
We describe a case of myeloneuropathy resulting from nitrous oxide abuse. MR imaging of the spine revealed symmetric abnormal signal in the posterior columns of the cervical cord. Myeloneuropathy is caused by inactivation of vitamin B12 by nitrous oxide. This syndrome can also be seen in patients with borderline vitamin B12 deficiency who have recently been anesthetized with nitrous oxide. |