Autor: |
Reeve F; Wright State University, Department of Orthopaedic Surgery, Dayton, Ohio 45409, USA., Laughlin RT, Wright DG |
Jazyk: |
angličtina |
Zdroj: |
Foot & ankle international [Foot Ankle Int] 1997 Jul; Vol. 18 (7), pp. 398-401. |
DOI: |
10.1177/107110079701800704 |
Abstrakt: |
Endoscopic plantar fascia release is a new procedure proposed to treat heel pain and plantar fasciitis. The purpose of this study was to assess the structures at risk during plantar fascia release using this method. Ten fresh-frozen cadaver feet were divided into two groups. All specimens underwent cannula placement inferior to the plantar fascia. Five-of the specimens had plantar fascia release using the endoscopic technique. Six of the specimens were then frozen and cut in transverse, sagittal, and coronal sections to visualize the relationship between the cannula and plantar fascia and surrounding structures. Gross dissection was performed on the remaining four specimens. The amount of plantar fascia released, the relationship to the nerve to abductor digiti minimi, and the fascia of the abductor hallucis muscle were assessed. The average distance from the cannula margin to the nerve to the abductor digiti minimi was 6 mm at the medial border of the plantar fascia. The average amount of plantar fascia released was 90%. Although a complete release was attempted, the fascia to the abductor hallucis was not released in any of the specimens. The nerve to the abductor digiti minimi was not damaged in any of the specimens. On coronal sections, the nerve was closer to the cannula and plantar fascia release than previously reported. |
Databáze: |
MEDLINE |
Externí odkaz: |
|