Coronary stenting for aortocoronary dissection following balloon angioplasty.

Autor: Seifein HB; Hoffman Heart Institute of Connecticut, St. Francis Hospital and Medical Center, Hartford 06105, USA., Missri JC, Warner MF
Jazyk: angličtina
Zdroj: Catheterization and cardiovascular diagnosis [Cathet Cardiovasc Diagn] 1996 Jun; Vol. 38 (2), pp. 222-5.
DOI: 10.1002/(SICI)1097-0304(199606)38:2<222::AID-CCD24>3.0.CO;2-J
Abstrakt: We report a case of coronary dissection following percutaneous transluminal coronary angioplasty (PTCA) in which the dissection extended antegrade as well as retrograde into the aortic root. Emergent stenting was able to seal the dissection entry point, resulting in restoration of normal coronary flow and diminution in the degree of aortic dissection.
Databáze: MEDLINE