Autor: |
Tisdel CL; Department of Orthopaedics, Case Western Reserve University School of Medicine, Cleveland, Ohio 44106., Goldberg VM, Parr JA, Bensusan JS, Staikoff LS, Stevenson S |
Jazyk: |
angličtina |
Zdroj: |
The Journal of bone and joint surgery. American volume [J Bone Joint Surg Am] 1994 Feb; Vol. 76 (2), pp. 159-71. |
DOI: |
10.2106/00004623-199402000-00001 |
Abstrakt: |
A study was done in rabbits to determine the effect of a hydroxyapatite and tricalcium-phosphate coating on bone growth into titanium fiber-metal implants. Titanium fiber rods with a solid titanium core were implanted bilaterally into the distal aspect of the femora of fifty-five New Zealand White rabbits. One rod was uncoated and the other rod was surface-coated with hydroxyapatite and tricalcium phosphate by the plasma-spray technique. Thirty-five rabbits were labeled sequentially with fluorochromes; killed at one, two, three, four, six, twelve, or twenty-four weeks after the operation; and studied histologically and histomorphometrically. The implants in the remaining twenty rabbits were subjected to pull-out testing to determine the shear strength at the implant-bone interface at three, six, twelve, and twenty-four weeks after the operation. Histomorphometry revealed significant effects of the hydroxyapatite and tricalcium-phosphate coating. When whole-group means (which included all time-points) were compared, it was found that 44 per cent of the perimeter of the hydroxyapatite and tricalcium-phosphate-coated implants was covered with bone compared with 12 per cent of the perimeter of the uncoated implants. The percentage of the internal surface of the implant that was covered with bone was also significantly higher in the hydroxyapatite and tricalcium-phosphate-coated implants: 27 per cent of the internal surface of the coated implants was covered compared with 8 per cent in the uncoated implants. The amount of bone in the pores of the implants was also higher in the hydroxyapatite and tricalcium-phosphate-coated implants: 12 per cent of the available pore space in the hydroxyapatite and tricalcium-phosphate-coated implants was filled with bone compared with 4 per cent in the uncoated implants. Scanning electron microscopy of the implants, done in backscatter mode, demonstrated apposition of new bone directly on the hydroxyapatite and tricalcium-phosphate coating, with variable degrees (amounts) of hydroxyapatite and tricalcium-phosphate resorption and new-bone replacement over time. Bone was never directly apposed to uncoated titanium fiber-metal. The pull-out strength of the hydroxyapatite and tricalcium-phosphate-coated implants was consistently greater than that of the uncoated implants, at all time-periods. |
Databáze: |
MEDLINE |
Externí odkaz: |
|