Autor: |
Leitch K; Glasgow and West of Scotland Blood Transfusion Service, Law Hospital, Lanarkshire, Scotland, UK., Forrest A, Mitchell R |
Jazyk: |
angličtina |
Zdroj: |
British journal of biomedical science [Br J Biomed Sci] 1993 Mar; Vol. 50 (1), pp. 64-6. |
Abstrakt: |
The gel test, first reported in 1988, can be used for most areas of blood group serology, but this report deals specifically with ABO/Rh typing and antibody screening and investigation. The technique is simple and quick to perform and the reading of results is standardised and clean with no false-positive reactions being found in antiglobulin tests. Since gel anti-human globulin tests require no washing and the test cards may be sealed during centrifugation, the system is particularly advantageous for 'loosely bound' antibodies and 'high-risk' samples. |
Databáze: |
MEDLINE |
Externí odkaz: |
|