Aortic paravalvular leaks: alternative suture placement strategy for the left coronary cusp.

Autor: Williams TE Jr; Grant Medical Center, Columbus, Ohio., Fanning WJ, Cattaneo SM
Jazyk: angličtina
Zdroj: The Annals of thoracic surgery [Ann Thorac Surg] 1995 Jan; Vol. 59 (1), pp. 243-4.
DOI: 10.1016/0003-4975(94)00872-5
Abstrakt: Repair of a left coronary cusp aortic paravalvular leak can be achieved by placing stitches through the main pulmonary artery, right pulmonary artery, and left atrium when removal of the previously inserted valve is contraindicated.
Databáze: MEDLINE