Autor: |
McMurphy RM; Department of Clinical Sciences, Kansas State University, College of Veterinary Medicine, Manhattan, USA., Hodgson DS, Cribb PH |
Jazyk: |
angličtina |
Zdroj: |
Veterinary surgery : VS [Vet Surg] 1995 Jul-Aug; Vol. 24 (4), pp. 352-5. |
DOI: |
10.1111/j.1532-950x.1995.tb01342.x |
Abstrakt: |
Barotrauma, pneumothorax, and pneumomediastinum occurred in two anesthetized cats in which the waste gas outlet of a nonrebreathing circuit was occluded. To prevent any similar cases of barotrauma, we have modified our nonrebreathing circuit adapters by inserting a 15 cm H2O PEEP valve into the gas pathway of the nonrebreathing circuit adapter. This PEEP valve prevents the circuit and airway pressures from exceeding 15 cm H2O if the pop-off valve of the nonrebreathing circuit adapter is inadvertently left closed. |
Databáze: |
MEDLINE |
Externí odkaz: |
|