High-frequency oscillation compared with standard ventilation in pulmonary injury model.

Autor: Thompson WK, Marchak BE, Froese AB, Bryan AC
Jazyk: angličtina
Zdroj: Journal of applied physiology: respiratory, environmental and exercise physiology [J Appl Physiol Respir Environ Exerc Physiol] 1982 Mar; Vol. 52 (3), pp. 543-8.
DOI: 10.1152/jappl.1982.52.3.543
Abstrakt: Hemorrhagic pulmonary edema was induced by intra-atrial infusion of 0.04--0.1 ml/kg of oleic acid into six anesthetized dogs. Gas exchange and cardiac outputs were then compared at identical mean airway pressures during randomized ventilation with either a volume-cycled ventilator with positive end-expiratory pressure (conventional positive-pressure ventilation, tidal volume 16--21 ml/kg, frequency 15--20 cycles/min) or a variable volume piston pump operating at 15 Hz (high-frequency oscillation). The fractional inspired oxygen concentration was maintained at 0.5 throughout. During 17 data sets matched for intratracheal mean airway pressures over a range of 7.5--27 cmH2O, measurements of systemic arterial pressure, arterial blood gas tensions, thermodilution cardiac outputs, and pulmonary arterial and capillary wedge pressures were identical (P less than 0.05) during ventilation with conventional positive-pressure ventilation and high-frequency oscillation. With both forms of ventilation, arterial oxygen tension progressively improved as mean airway pressure increased. In a shunt model of acute lung injury we were unable to show significant differences in oxygenation or cardiac output when high-frequency oscillation was compared with conventional positive-pressure ventilation with positive end-expiratory pressure at equivalent mean airway pressures.
Databáze: MEDLINE