[Fractionation of nucleosides and nucleoside-5'-mono-, di and triphosphates by thin layer chromatography in silufol].

Autor: Kudelin BK, Kaminskiĭ IuL, Ivanova IF, Gavrilin SS
Jazyk: ruština
Zdroj: Biokhimiia (Moscow, Russia) [Biokhimiia] 1979 Feb; Vol. 44 (2), pp. 368-71.
Abstrakt: New solvent systems--dioxane--isopropanol--water--ammonium (4:2:4:1) and dioxane--water--ammonium (6:4:1)--for rapid qualitative and quantitative estimation of nucleosides, nucleoside-5'-mono-, di- and triphosphates by thin layer chromatography is Silufol UV-254 are proposed. The Rf values for 40 ribo- and deoxyribonucleotides of these systems are given.
Databáze: MEDLINE