Autor: |
Hill WF Jr, Hamblet FE, Akin EW |
Jazyk: |
angličtina |
Zdroj: |
Applied microbiology [Appl Microbiol] 1967 May; Vol. 15 (3), pp. 533-6. |
DOI: |
10.1128/am.15.3.533-536.1967 |
Abstrakt: |
The effectiveness of a model ultraviolet (UV) radiation unit for treating flowing turbid seawater contaminated with poliovirus was determined. At a turbidity of 70 ppm, the observed survival ratios ranged from 1.9 x 10(-3) (99.81% reduction) to 1.5 x 10(-4) (99.98% reduction) at flow rates ranging from 25 to 15 liters/min; no virus was recovered at flow rates of 10 and 5 liters/min. At a turbidity of 240 ppm, the observed survival ratios ranged from 3.2 x 10(-2) (96.80% reduction) to 2.1 x 10(-4) (99.98% reduction) at flow rates ranging from 25 to 5 liters/min. As expected, turbidity had an adverse influence on the effectiveness of UV radiation; however, by adjusting the flow rate of the seawater through the treatment unit, adequate disinfection was shown to be predictable. |
Databáze: |
MEDLINE |
Externí odkaz: |
|