Evaluation of Multiplex loop-mediated isothermal amplification assay for the detection of Mycobacterium tuberculosis complex from clinically suspected cases of pulmonary tuberculosis.

Autor: Zaber M; Department of Microbiology, Gazi Medical College, Khulna, Bangladesh., Hoque F; Department of Microbiology, Sheikh Hasina Medical College, Jamalpur, Bangladesh., Paean IM; Armed Forces Medical College, Bangladesh., Tarafder S; Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, 1000, Bangladesh.
Jazyk: angličtina
Zdroj: Heliyon [Heliyon] 2024 Oct 24; Vol. 10 (21), pp. e39847. Date of Electronic Publication: 2024 Oct 24 (Print Publication: 2024).
DOI: 10.1016/j.heliyon.2024.e39847
Abstrakt: Tuberculosis (TB) is the second leading cause of death from a single infectious agent worldwide. Bangladesh ranks 7th among the 30 high TB burdened countries in the world. Accurate detection of Mycobacterium tuberculosis complex (MTBC) is challenging for developing countries as most of the resource poor settings are not suitable to perform molecular techniques. The purpose of the study was to compare the multiplex TB-LAMP assay with MTB/NTM qPCR, culture, Z-N staining, and fluorescence microscopy in order to assess the effectiveness of the LAMP assay for detecting cases of pulmonary tuberculosis. This research work was done from March 2022 to February 2023. Fulfilling the inclusion criteria 130 sputum samples were collected. TB-LAMP assay, qPCR, culture in L-J media, Z-N staining and fluorescence microscopy were performed. Out of 130 samples qPCR detected MTBC in 56.92 % cases and TB-LAMP detected 53.85 %. MTBC was detected by culture 46.15 %, by Fluorescence microscopy 40.77 % and Z-N staining 36.92 %. TB-LAMP detected 16.93 % more cases than Z-N staining and 13.08 % more cases than fluorescence microscopy. The sensitivity, specificity, positive, and negative predictive values of multiplex-LAMP assay were 95 %, 81.4 %, 81.4 % and 95 % respectively considering culture as a gold-standard. MTBC negative culture samples (18.57 %) showed positivity by LAMP assay as well as by qPCR. This study detected 7.69 % non-tuberculous mycobacteria (NTM) by qPCR. All NTM positive samples were negative by TB-LAMP. TB-LAMP is an easy to perform, cost-effective, reliable assay with high sensitivity and specificity. World Health Organization recommended TB-LAMP as a rapid molecular test for rapid detection of tuberculosis and as replacement of microscopy in resource poor settings/hard to reach areas. Bangladesh being a high TB burden country it is essential to implement TB-LAMP to achieve End TB Strategy by 2035.
Competing Interests: The authors declare that they have no competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(© 2024 The Authors. Published by Elsevier Ltd.)
Databáze: MEDLINE