Image quality of virtual monochromatic and material density iodine images for evaluation of head and neck neoplasms using deep learning-based CT image reconstruction - A retrospective observational study.
Autor: | Bürckenmeyer F; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: florian.buerckenmeyer@med.uni-jena.de., Gräger S; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: stephanie.graeger@med.uni-jena.de., Mlynska L; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: lucja.mlynska@med.uni-jena.de., Güttler F; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: felix.guettler@med.uni-jena.de., Ingwersen M; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: maja.ingwersen@gmx.de., Teichgräber U; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: ulf.teichgraeber@med.uni-jena.de., Krämer M; Friedrich-Schiller-University Jena, Jena University Hospital, Department of Diagnostic and Interventional Radiology, Jena, Germany. Electronic address: martin.kraemer@med.uni-jena.de. |
---|---|
Jazyk: | angličtina |
Zdroj: | European journal of radiology [Eur J Radiol] 2024 Dec; Vol. 181, pp. 111806. Date of Electronic Publication: 2024 Oct 25. |
DOI: | 10.1016/j.ejrad.2024.111806 |
Abstrakt: | Purpose: To compare the quality of deep learning image reconstructed (DLIR) virtual monochromatic images (VMI) and material density (MD) iodine images from dual-energy computed tomography (DECT) for the evaluation of head and neck neoplasms with CT scans from a conventional single-energy protocol. Method: A total of 294 head and neck CT scans (98 VMIs operated at 60 keV, 102 MD iodine images, and 94 images from a 120 kVp single-energy CT (SECT) protocol) were retrospectively evaluated. VMIs and MD iodine images were generated using the Gemstone Spectral Imaging (GSI) mode using DLIR and metal artifact reduction (MAR) algorithms. SECT images were generated using adaptive statistical iterative reconstruction (ASIR-V). Images were scored by two independent readers on a 6-point Likert-type scale for overall image quality, vessel contrast, soft tissue contrast, noise texture, noise intensity, artifact reduction, and sharpness. Results: Subjective overall image quality was rated as superior or excellent in 98 % of DLIR-based MD iodine images and VMIs, but only in 55 % of ASIR-V-based SECT images. For each individual quality criterion, image quality of VMIs and MD iodine images was rated as better than that of SECT images (p < 0.001 in each case). Noise texture and intensity were rated better in MD iodine images than in VMIs. Conclusion: DECT using both DLIR and MAR for the generation of VMIs and MD iodine images resulted in higher subjective quality of oncologic head and neck images than ASIR-V-based SECT. Noise reduction and noise texture were best achieved with DLIR-based MD iodine images. Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |