A wearable real-time particulate monitor demonstrates that soaking hay reduces dust exposure.
Autor: | Ivester KM; College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA., Ni JQ; Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, Indiana, USA., Couetil LL; College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA., Peters TM; Department of Occupational and Environmental Health, University of Iowa, Iowa City, Iowa, USA., Tatum M; Department of Occupational and Environmental Health, University of Iowa, Iowa City, Iowa, USA., Willems L; College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA., Park JH; School of Health Sciences, Purdue University, West Lafayette, Indiana, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Equine veterinary journal [Equine Vet J] 2024 Oct 27. Date of Electronic Publication: 2024 Oct 27. |
DOI: | 10.1111/evj.14425 |
Abstrakt: | Background: Affordable particulate matter (PM) monitors suitable for use on horses will facilitate the evaluation of PM mitigation methods and improve the management of equine asthma. Objective: Calibrate a real-time wearable PM monitor (Black Beauty [BB]) and compare the PM exposures of horses fed dry or soaked hay. Study Design: Laboratory calibration; complete cross-over feed trial. Methods: Side-by-side sampling with BB monitors and tapered element oscillating microbalances (TEOMs) was performed under varying concentrations of PM from alfalfa hay. Linear regression was used to derive a calibration formula for each unit based on TEOM PM measurements. Precision was evaluated by calculating the coefficient of variation and pairwise correlation coefficients between three BB monitors. PM exposure was measured at the breathing zone of 10 horses for 8 h after they were fed dry or soaked hay. Repeated measures generalised linear models were constructed to determine the effect of hay treatment and measurement duration (initial 20-min vs. 8-h) upon exposure to PM with diameters smaller than or equal to 10 μm (PM Results: BB monitor PM Main Limitations: No health outcome measures were collected. Conclusions: With appropriate corrections, the BB monitor can be used to estimate horse PM exposure. While 20-min measurements yielded higher estimates of exposure than 8-h measurements, both intervals demonstrate that soaking hay reduces PM exposures by more than 50%. (© 2024 The Author(s). Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.) |
Databáze: | MEDLINE |
Externí odkaz: |