Lymphoscintigraphy With SPECT-CT in Detecting the Site of Chyle Leak in Postoperative Patient.

Autor: Gokhale SM; From the Department of Nuclear Medicine, Inlaks and Budhrani Hospital, Sadhu Vaswani Mission's Medical Complex., Bhatia M; Department of Surgical Oncology, M.N.B.C.I, Sadhu Vaswani Mission's Medical Complex, Pune, India.
Jazyk: angličtina
Zdroj: Clinical nuclear medicine [Clin Nucl Med] 2024 Dec 01; Vol. 49 (12), pp. e664-e667. Date of Electronic Publication: 2024 Oct 14.
DOI: 10.1097/RLU.0000000000005496
Abstrakt: Abstract: Here is a case of chyle leak post McKeown esophagectomy. Lymphoscintigraphy with 99m Tc-filtered sulfur colloid revealed tracer accumulation along the thoracic duct and in the left hemithorax. Precise localization of leak was done by SPECT-CT imaging. This enabled timely surgical intervention and reduced further morbidity. This procedure is not only precise but also cost-effective as compared with the other available investigations.
Competing Interests: Conflicts of interest and sources of funding: none declared.
(Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)
Databáze: MEDLINE