Active-bromide and surfactant synergy for enhanced microfouling control.

Autor: Shukla SK; Biofouling and Biofilm Processes Section, Water & Steam Chemistry Division, Bhabha Atomic Research Centre Facilities, Kalpakkam, 603102, India. skshukla@igcar.gov.in.; Homi Bhabha National Institute, Mumbai, 400094, India. skshukla@igcar.gov.in., Rao TS; School of Arts & Sciences, Sai University, OMR, Chennai, 603104, India. subbarao.t@saiuniversity.edu.in., N M; Biofouling and Biofilm Processes Section, Water & Steam Chemistry Division, Bhabha Atomic Research Centre Facilities, Kalpakkam, 603102, India., Mohan TVK; Water & Steam Chemistry Division, Bhabha Atomic Research Centre Facilities, Kalpakkam, 603102, India.
Jazyk: angličtina
Zdroj: Archives of microbiology [Arch Microbiol] 2024 Oct 10; Vol. 206 (11), pp. 430. Date of Electronic Publication: 2024 Oct 10.
DOI: 10.1007/s00203-024-04154-6
Abstrakt: Biofilms are structured microbial communities encased in a matrix of self-produced extracellular polymeric substance (EPS) and pose significant challenges in various industrial cooling systems. A nuclear power plant uses a biocide active-bromide for control of biological growth in its condenser cooling system. This study is aimed at evaluating the anti-bacterial and anti-biofilm efficacy of active-bromide against planktonic and biofilm-forming bacteria that are commonly encountered in seawater cooling systems. The results demonstrated that active-bromide at the concentration used at the power plant (1 ppm) exhibited minimal killing activity against Pseudomonas aeruginosa planktonic cells. The bacterial cell surface hydrophobicity assay using Staphylococcus aureus and P. aeruginosa indicated that Triton-X 100 significantly decreased the hydrophobicity of planktonic cells, enhancing the susceptibility of the cells to active-bromide. Biofilm inhibition assays revealed limited efficacy of active-bromide at 1 ppm concentration, but significant inhibition at 5 ppm and 10 ppm. However, the addition of a surfactant, Triton-X 100, in combination with 1 ppm active-bromide displayed a synergistic effect, leading to significant biofilm dispersal of pre-formed P. aeruginosa biofilms. This observation was substantiated by epifluorescence microscopy using a live/dead bacterial assay that showed the combination treatment resulted in extensive cell death within the biofilm, as indicated by a marked increase in red fluorescence, compared to treatments with either agent alone. These findings suggest that active bromide alone may be insufficient for microfouling control in the seawater-based condenser cooling system of the power plant. Including a biocompatible surfactant that disrupts established biofilms (microfouling) can significantly improve the efficacy of active bromide treatment.
(© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
Databáze: MEDLINE