Equipping computational pathology systems with artifact processing pipelines: a showcase for computation and performance trade-offs.
Autor: | Kanwal N; Department of Electrical Engineering and Computer Science, University of Stavanger, 4021, Stavanger, Norway. neel.kanwal@uis.no., Khoraminia F; Department of Urology, University Medical Center Rotterdam, Erasmus MC Cancer Institute, 1035 GD, Rotterdam, The Netherlands., Kiraz U; Department of Pathology, Stavanger University Hospital, 4011, Stavanger, Norway.; Department of Chemistry, Bioscience and Environmental Engineering, University of Stavanger, 4021, Stavanger, Norway., Mosquera-Zamudio A; Department of Pathology, INCLIVA Biomedical Research Institute, and University of Valencia, 46010, Valencia, Spain., Monteagudo C; Department of Pathology, INCLIVA Biomedical Research Institute, and University of Valencia, 46010, Valencia, Spain., Janssen EAM; Department of Pathology, Stavanger University Hospital, 4011, Stavanger, Norway.; Department of Chemistry, Bioscience and Environmental Engineering, University of Stavanger, 4021, Stavanger, Norway., Zuiverloon TCM; Department of Urology, University Medical Center Rotterdam, Erasmus MC Cancer Institute, 1035 GD, Rotterdam, The Netherlands., Rong C; Department of Electrical Engineering and Computer Science, University of Stavanger, 4021, Stavanger, Norway., Engan K; Department of Electrical Engineering and Computer Science, University of Stavanger, 4021, Stavanger, Norway. kjersti.engan@uis.no. |
---|---|
Jazyk: | angličtina |
Zdroj: | BMC medical informatics and decision making [BMC Med Inform Decis Mak] 2024 Oct 07; Vol. 24 (1), pp. 288. Date of Electronic Publication: 2024 Oct 07. |
DOI: | 10.1186/s12911-024-02676-z |
Abstrakt: | Background: Histopathology is a gold standard for cancer diagnosis. It involves extracting tissue specimens from suspicious areas to prepare a glass slide for a microscopic examination. However, histological tissue processing procedures result in the introduction of artifacts, which are ultimately transferred to the digitized version of glass slides, known as whole slide images (WSIs). Artifacts are diagnostically irrelevant areas and may result in wrong predictions from deep learning (DL) algorithms. Therefore, detecting and excluding artifacts in the computational pathology (CPATH) system is essential for reliable automated diagnosis. Methods: In this paper, we propose a mixture of experts (MoE) scheme for detecting five notable artifacts, including damaged tissue, blur, folded tissue, air bubbles, and histologically irrelevant blood from WSIs. First, we train independent binary DL models as experts to capture particular artifact morphology. Then, we ensemble their predictions using a fusion mechanism. We apply probabilistic thresholding over the final probability distribution to improve the sensitivity of the MoE. We developed four DL pipelines to evaluate computational and performance trade-offs. These include two MoEs and two multiclass models of state-of-the-art deep convolutional neural networks (DCNNs) and vision transformers (ViTs). These DL pipelines are quantitatively and qualitatively evaluated on external and out-of-distribution (OoD) data to assess generalizability and robustness for artifact detection application. Results: We extensively evaluated the proposed MoE and multiclass models. DCNNs-based MoE and ViTs-based MoE schemes outperformed simpler multiclass models and were tested on datasets from different hospitals and cancer types, where MoE using (MobileNet) DCNNs yielded the best results. The proposed MoE yields 86.15 % F1 and 97.93% sensitivity scores on unseen data, retaining less computational cost for inference than MoE using ViTs. This best performance of MoEs comes with relatively higher computational trade-offs than multiclass models. Furthermore, we apply post-processing to create an artifact segmentation mask, a potential artifact-free RoI map, a quality report, and an artifact-refined WSI for further computational analysis. During the qualitative evaluation, field experts assessed the predictive performance of MoEs over OoD WSIs. They rated artifact detection and artifact-free area preservation, where the highest agreement translated to a Cohen Kappa of 0.82, indicating substantial agreement for the overall diagnostic usability of the DCNN-based MoE scheme. Conclusions: The proposed artifact detection pipeline will not only ensure reliable CPATH predictions but may also provide quality control. In this work, the best-performing pipeline for artifact detection is MoE with DCNNs. Our detailed experiments show that there is always a trade-off between performance and computational complexity, and no straightforward DL solution equally suits all types of data and applications. The code and HistoArtifacts dataset can be found online at Github and Zenodo , respectively. (© 2024. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |