Autor: |
Divarova VV; Department of Chemical Sciences, Faculty of Pharmacy, Medical University of Plovdiv. vidka.divarova@mu-plovdiv.bg., Stojnova KT; Department of General and Inorganic Chemistry with Methodology of Chemistry Education, Faculty of Chemistry, Plovdiv University 'Paisii Hilendarski'. kirila_stoinova@abv.bg., Radkovska ID; Faculty of Pharmacy, Medical University of Plovdiv. 22301073@mu-plovdiv.bg., Saravanska AD; Department of Chemical Sciences, Faculty of Pharmacy, Medical University of Plovdiv. antoaneta.saravanska@mu-plovdiv.bg., Toncheva GK; Department of General and Inorganic Chemistry with Methodology of Chemistry Education, Faculty of Chemistry, Plovdiv University 'Paisii Hilendarski'. galq_toncheva@mail.bg., Delchev VB; Department of Physical Chemistry, Faculty of Chemistry, Plovdiv University 'Paisii Hilendarski'. vdelchev@uni-plovdiv.net., Gavazov KB; Medical University of Plovdiv. kgavazov@abv.bg. |
Jazyk: |
angličtina |
Zdroj: |
Acta chimica Slovenica [Acta Chim Slov] 2024 Sep 10; Vol. 71 (3), pp. 519-527. Date of Electronic Publication: 2024 Sep 10. |
DOI: |
10.17344/acsi.2024.8835 |
Abstrakt: |
A novel chromogenic system for the liquid-liquid extraction and determination of trace amounts of tungsten(VI) was investigated. The system comprises 4-nitrocatechol (4NC) as a chromogenic reagent, sulfuric acid as a complexing medium, and benzalkonium chloride (BAC) as a source of bulky cations (BA+), which readily form chloroform-extractable ion-association complexes. The impact of foreign ions and reagents was studied, and the optimal conditions for the sensitive, selective, and inexpensive determination of tungsten(VI) were identified. The limit of detection, linear working range, and molar absorptivity at lmax (422 nm) were determined to be 31 ng cm-3, 0.1-4.4 µg cm-3, and 5.49 × 104 dm3 mol-1 cm-1, respectively. The composition of the extracted complex was 1:2:2 (W:4NC:BA). Two potential structures of its anionic component, [WO2(4NC)2]2-, were discussed based on optimizations at the B3LYP/CEP-4G theoretical level and comparison between theoretical and experimental spectra. |
Databáze: |
MEDLINE |
Externí odkaz: |
|