Concurrent Validity and Reliability of a Free Smartphone Application for Evaluation of Jump Height.

Autor: Dias A; Egas Moniz Center for Interdisciplinary Research (CiiEM), Egas Moniz School of Health & Science, Caparica, 2829-511 Almada, Portugal.; Integrative Movement and Networking Systems Laboratory (INMOV-NET LAB), Egas Moniz Center for Interdisciplinary Research (CiiEM), Egas Moniz School of Health & Science, Caparica, 2829-511 Almada, Portugal.; Sport Physical Activity and Health Research & Innovation Center (SPRINT), 2040-413 Rio Maior, Portugal., Pires P; Centre for the Study of Human Performance (CIPER), Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada-Dafundo, 1499-002 Lisboa, Portugal.; Hospital da Luz, 1500-650 Lisboa, Portugal., Santana L; Postgraduate Program in Physical Education, Federal University of Juiz de Fora, Juíz de Fora 36036-900, Brazil., Marques P; Faculty of Physical Education and Sport, Lusófona University, 1749-024 Lisbon, Portugal., Espada MC; Sport Physical Activity and Health Research & Innovation Center (SPRINT), 2040-413 Rio Maior, Portugal.; Centre for the Study of Human Performance (CIPER), Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada-Dafundo, 1499-002 Lisboa, Portugal.; Instituto Politécnico de Setúbal, Escola Superior de Educação, 2914-504 Setúbal, Portugal.; Life Quality Research Centre (CIEQV-Leiria), 2040-413 Rio Maior, Portugal.; Comprehensive Health Research Centre (CHRC), Universidade de Évora, 7004-516 Évora, Portugal.; Life Quality Research Centre (CIEQV-Setúbal), 2914-504 Setúbal, Portugal., Santos F; Instituto Politécnico de Setúbal, Escola Superior de Educação, 2914-504 Setúbal, Portugal.; Life Quality Research Centre (CIEQV-Leiria), 2040-413 Rio Maior, Portugal.; Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada-Dafundo, 1499-002 Lisboa, Portugal., Silva EJD; Faculty of Physical Education and Sport, Lusófona University, 1749-024 Lisbon, Portugal.; CIDEFES, Centro de Investigação em Desporto, Educação Física e Exercício e Saúde, Universidade Lusófona, 1749-024 Lisbon, Portugal., Rebelo A; CIDEFES, Centro de Investigação em Desporto, Educação Física e Exercício e Saúde, Universidade Lusófona, 1749-024 Lisbon, Portugal.; COD, Center of Sports Optimization, Sporting Clube de Portugal, 1600-464 Lisbon, Portugal., Teixeira DS; Faculty of Physical Education and Sport, Lusófona University, 1749-024 Lisbon, Portugal.; CIDEFES, Centro de Investigação em Desporto, Educação Física e Exercício e Saúde, Universidade Lusófona, 1749-024 Lisbon, Portugal.
Jazyk: angličtina
Zdroj: Journal of functional morphology and kinesiology [J Funct Morphol Kinesiol] 2024 Sep 01; Vol. 9 (3). Date of Electronic Publication: 2024 Sep 01.
DOI: 10.3390/jfmk9030155
Abstrakt: Background/Objectives : Jump test assessment is commonly used for physical tests, with different type of devices used for its evaluation. The purpose of the present study was to examine the validity and reliability of a freely accessible mobile application (VertVision, version 2.0.5) for measuring jump performance. Methods: With that intent, thirty-eight college age recreationally active subjects underwent test assessment after a specific warm-up, performing countermovement jumps (CMJs) and squat jumps (SJs) on a contact platform while being recorded with a smartphone camera. Jump height was the criterion variable, with the same formula being used for both methods. Data analysis was performed by two experienced observers. Results: The results showed strong correlations with the contact platform (ICC > 0.9) for both jumps. Furthermore, between-observer reliability was also high (ICC > 0.9; CV ≤ 2.19), with lower values for smallest worthwhile change (≤0.23) and typical error of measurement (≤0.14). Estimation error varied when accounting for both observers, with the SJ accounting for bigger differences (4.1-6.03%), when compared to the CMJ (0.73-3.09%). Conclusions: The study suggests that VertVision is a suitable and handy method for evaluating jump performance. However, it presents a slight estimation error when compared to the contact platform.
Databáze: MEDLINE