The value of shear wave elastography combined with red blood cell distribution width in evaluating arterial erectile dysfunction.
Autor: | Wang Q; Department of Ultrasound, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, Anhui, China., Guo Y; Department of Ultrasound, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, Anhui, China., Zhang H; Department of Ultrasound, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, Anhui, China., Qin X; Department of Ultrasound, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, Anhui, China., Zhang C; Department of Ultrasound, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, Anhui, China. zcxay@163.com., Zhou W; Department of Ultrasound, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Shushan District, Hefei, Anhui, China. zhouwangayfycsk@163.com.; School of Pharmacy, Inflammation and Immune Mediated Diseases Laboratory of Anhui Province, Anhui Medical University, Hefei, Anhui, China. zhouwangayfycsk@163.com. |
---|---|
Jazyk: | angličtina |
Zdroj: | BMC urology [BMC Urol] 2024 Sep 19; Vol. 24 (1), pp. 205. Date of Electronic Publication: 2024 Sep 19. |
DOI: | 10.1186/s12894-024-01579-5 |
Abstrakt: | Purpose: A retrospective study was conducted to determine the value of shear wave elastography (SWE) and red blood cell distribution width (RDW) in the diagnosis of various forms of erectile dysfunction (ED). Methods: With the method of Nocturnal Penile Tumescence and Rigidity (NPTR) and the screening method of Color Duplex Doppler Ultrasound (CDDU), hematological data were collected from 131 individuals, among whom 24 are with psychogenic ED, 48 are with non-arterial ED(NAED) and 59 are with arterial ED(AED) with erectile dysfunction. SWE value of penile corpus cavernosum(CCP) and cavernous arterial flow velocity were measured before (flaccid state) and after (erect state) intracavernous injection (ICI) in all patients. Results: Among the AED patients and other types of ED patients, there were statistically significant differences in the abridged five-item International Index of Erectile Function (IIEF-5), red blood cell distribution width-coefficient of variation (RDW-CV), red blood cell distribution width-standard deviation (RDW-SD), and SWE values (all P < 0.01). In the AED patients, the IIEF-5 scores had a significant negative relationship with RDW-CV, RDW-SD, and SWE values, with SWE values having the strongest correlation. (p < 0.001, r=-0.638). Conclusion: The combination of RDW level and SWE value demonstrated the greatest performance in diagnosing AED, according to the receiver-operator characteristic(ROC) curve analysis (AUC = 0.870, p < 0.0001, cut-off value of 0.75, sensitivity of 74.6%, specificity of 91.7%).RDW and SWE value may develop into an incredibly simple, practical tool for predicting and diagnosing AED. Trial Registration: retrospectively registered. (© 2024. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: |