Preparation and application of multiple particle binding-liposomes for electrochemiluminescent signal amplification in bioassays.

Autor: Tanaka A; Laboratory of Analytical Chemistry, Kyoto Pharmaceutical University, 5 Misasaginakauchi-cho, Yamashina-ku, Kyoto, 607-8414, Japan., Konishi A; Laboratory of Analytical Chemistry, Kyoto Pharmaceutical University, 5 Misasaginakauchi-cho, Yamashina-ku, Kyoto, 607-8414, Japan., Takegami S; Laboratory of Analytical Chemistry, Kyoto Pharmaceutical University, 5 Misasaginakauchi-cho, Yamashina-ku, Kyoto, 607-8414, Japan. takegami@mb.kyoto-phu.ac.jp.
Jazyk: angličtina
Zdroj: Analytical and bioanalytical chemistry [Anal Bioanal Chem] 2024 Nov; Vol. 416 (28), pp. 6451-6461. Date of Electronic Publication: 2024 Sep 14.
DOI: 10.1007/s00216-024-05532-1
Abstrakt: In this study, multiple particle binding-liposomes (MPB-Lips), encapsulating the luminophore tris(2',2-bipyridyl)ruthenium (II) complex ([Ru(bpy) 3 ] 2+ ), were developed as an electrochemiluminescence (ECL) signal amplifier and were applied to detect the model analyte streptavidin (SA) using the indirect competitive ECL method. The MPB-Lips were prepared by mixing various ratios of two different liposomes-one containing a phospholipid with a primary amine group and a biotinyl group (BIO/NH 2 -Lip) and one containing a phospholipid with an N-hydroxysuccinimide group (NHS-Lip) to allow binding between particles via amide bonds. Quartz crystal microbalance analysis using SA-modified gold-coated quartz crystals showed that the frequency shift values of MPB-Lips gradually decreased in the order BIO/NH 2 -Lip:NHS-Lip = 1:0 < 1:1 < 1:3 < 1:5. This indicated that MPB-Lips were successfully formed. The indirect competitive ECL method using SA-modified gold electrodes showed that the 1:5-Lip system had greater sensitivity than the 1:0-Lip system-the limit of detection and quantification values for the systems were 1.84 and 6.30 μg mL -1 for 1:0-Lip, and 1.20 and 1.74 μg mL -1 for 1:5-Lip. Finally, the recovery of SA spiked in fetal bovine serum samples using the 1:5-Lip system showed good accuracy and precision with a recovery rate of 83-106% and relative standard deviation of 4-14%. Our study demonstrated that the MPB-Lips system was an effective and useful ECL amplifier and the ECL method using MPB-Lips could be applied to detect an analyte in a real sample.
(© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH, DE part of Springer Nature.)
Databáze: MEDLINE