Microvolumetric determination of thrombomodulin based on competitive immunoreaction using a portable glucometer.

Autor: Luo P; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, People's Republic of China., Xie Y; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, People's Republic of China., He X; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, People's Republic of China., Zhang W; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, People's Republic of China., Tan L; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, People's Republic of China. liangtan@hunnu.edu.cn.
Jazyk: angličtina
Zdroj: Mikrochimica acta [Mikrochim Acta] 2024 Sep 09; Vol. 191 (10), pp. 585. Date of Electronic Publication: 2024 Sep 09.
DOI: 10.1007/s00604-024-06671-z
Abstrakt: A new method of reducing the amount of reagent and sample for determination of thrombomodulin (TM) was developed based on competitive immunoreaction using a portable glucometer (PGM). Two types of nanocomposites, TM protein-modified magnetic nanoparticles (MNPs-TM) and TM antibody-/glucose oxidase-modified gold nanoparticles (Ab-GNPs-GOx), were prepared. Their binding product, MNPs-TM-Ab-GNPs-GOx, in the microvolumetric solution was used to catalyze the oxidation of glucose, leading to a decline of the glucose content. The TM-involved competitive immunoreaction had a negative effect on the generation of MNPs-/GNPs-based nanocomposites and inhibited the catalytic oxidation of glucose. The glucose content difference in the microvolumetric solution, which was revealed by a PGM, was in proportion to the logarithm of the TM concentration from 25 ng mL -1 to 2.5 μg mL -1 . The limit of detection was 5.7 ng mL -1 . Microvolumetric solution and a PGM were used in the measurement, which overcame some deficiencies of classical methods in chemo/biosensing, for example, special instrument, complicated measurement procedure, and high cost.
(© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.)
Databáze: MEDLINE