A harsh environmental resistant and long-term stable ionic conductive hydrogel by one-step preparation for wireless health activity and physiological state detection.

Autor: Huang G; Engineering Research Centre of Large Scale Reactor Engineering and Technology, Ministry of Education, School of Chemical Engineering, East China University of Science and Technology, 130 Meilong Road, Shanghai 200237, China; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China., Miao H; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China; University of Chinese Academy of Sciences, Beijing 100049, China., Zhang X; Public Technology Service Center of Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200062, China., Zheng C; Department of Oral and Maxillofacial-Head & Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China., Huang X; Department of Oral and Maxillofacial-Head & Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China., Liu Y; Phonon Science Research Center for Carbon Dioxide, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China., He Y; Engineering Research Centre of Large Scale Reactor Engineering and Technology, Ministry of Education, School of Chemical Engineering, East China University of Science and Technology, 130 Meilong Road, Shanghai 200237, China; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China., Fu X; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China., Ge M; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China., Huang H; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China. Electronic address: huanghailong@sinap.ac.cn., Zhang R; Engineering Research Centre of Large Scale Reactor Engineering and Technology, Ministry of Education, School of Chemical Engineering, East China University of Science and Technology, 130 Meilong Road, Shanghai 200237, China. Electronic address: r.zhang@ecust.edu.cn., Liu H; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China. Electronic address: liuhongtao@sinap.ac.cn., Qian Y; Key Laboratory of Interfacial Physics and Technology and Department of Molten Salt Chemistry and Engineering, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, No. 2019 Jialuo Road, Shanghai 201800, China.
Jazyk: angličtina
Zdroj: International journal of biological macromolecules [Int J Biol Macromol] 2024 Nov; Vol. 279 (Pt 4), pp. 135286. Date of Electronic Publication: 2024 Sep 06.
DOI: 10.1016/j.ijbiomac.2024.135286
Abstrakt: Benefiting from the good electromechanical performance, ionic conductive hydrogel can easily convert the deformation into electrical signals, showing great potential in wearable electronic devices. However, due to the high water content, icing and water evaporation problems seriously limit their development. Although additives can ease these disadvantages, the accompanying performance degradation and complex preparation processes couldn't meet application needs. In this work, a convenient method was provided to prepare ionic conductive hydrogels with sensitive electromechanical performance, harsh environmental tolerance, and long-term stability without additives. Based on the hydratability between metal ions and water molecules resulting in spatial condensation of the hydrogel framework, the hydrogel exhibits good flexibility and ionic conductivity (70.3 mS/cm). Furthermore, the metal salt can bind with water molecules to reduce the vapor pressure, thus endowing the hydrogel with good freezing resistance (-40 °C) and long-term stability over a wide temperature range (-20 °C-50 °C). Based on these unique advantages, the hydrogel shows good sensitivity. Even in a harsh environment, it still maintained excellent stability (-20 °C-50 °C, GF = 2.2, R 2  > 0.99). Assembled with a Wi-Fi device, the hydrogel sensor demonstrates good health activity and physiological state detection performance, demonstrating great potential for wearable medical devices.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2024 Elsevier B.V. All rights reserved.)
Databáze: MEDLINE