Evaluation of the Mechanical Behavior of the Patellar and Semitendinosus Tendons Using Supersonic Shear-wave Imaging (SSI) Elastography and Tensile Tests.
Autor: | Fontenelle A; Serviço de Traumato-Ortopedia, Hospital Universitário Clementino Fraga Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil., Mannarino P; Departamento de Ortopedia e Traumatologia, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil., Oliveira LF; Programa de Engenharia Biomédica, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (Coppe), Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil., Menegaldo LL; Programa de Engenharia Biomédica, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (Coppe), Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil., Souza SAL; Departamento de Radiologia, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil., Fontenelle CRDC; Serviço de Traumato-Ortopedia, Hospital Universitário Clementino Fraga Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil. |
---|---|
Jazyk: | angličtina |
Zdroj: | Revista brasileira de ortopedia [Rev Bras Ortop (Sao Paulo)] 2024 Sep 04; Vol. 59 (4), pp. e556-e563. Date of Electronic Publication: 2024 Sep 04 (Print Publication: 2024). |
DOI: | 10.1055/s-0044-1788290 |
Abstrakt: | Objective To analyze the mechanical properties of the patellar (PT) and semitendinosus (ST) tendons from fresh-frozen human cadavers from a tissue bank using supersonic shear-wave imaging (SSI) elastography and tensile tests. Methods We tested seven PT and five ST samples on a traction machine and performed their simultaneous assessment through SSI. The measurements enabled the comparison of the mechanical behavior of the tendons using the stress x strain curve and shear modulus (μ) at rest. In addition, we analyzed the stress x μ relationship under tension and tested the relationship between these parameters. The statistical analysis of the results used unpaired t -tests with Welch correction, the Pearson correlation, and linear regression for the Young modulus (E) estimation. Results The μ values for the PT and ST at rest were of 58.86 ± 5.226 kPa and 124.3 ± 7.231 kPa respectively, and this difference was statistically significant. The correlation coefficient between stress and μ for the PT and ST was very strong. The calculated E for the PT and ST was of 19.97 kPa and 124.8 kPa respectively, with a statistically significant difference. Conclusion The ST was stiffer than the PT in the traction tests and SSI evaluations. The μ value was directly related to the stress imposed on the tendon. Clinical relevance The present is an evaluation of the mechanical properties of the tendons most used as grafts in knee ligament reconstruction surgeries. Competing Interests: Conflito de Interesses Os autores não têm conflito de interesses a declarar. (The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution 4.0 International License, permitting copying and reproduction so long as the original work is given appropriate credit ( https://creativecommons.org/licenses/by/4.0/ ).) |
Databáze: | MEDLINE |
Externí odkaz: |