[Design and simulation study of positive pressure ventilation system in a simulated human biological lung].
Autor: | Yan Q; School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, P. R. China., Wu Q; School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, P. R. China., Zhang W; School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, P. R. China., Pan L; School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, P. R. China., Liu X; School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, P. R. China., Tao W; School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, P. R. China. |
---|---|
Jazyk: | čínština |
Zdroj: | Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi [Sheng Wu Yi Xue Gong Cheng Xue Za Zhi] 2024 Aug 25; Vol. 41 (4), pp. 775-781. |
DOI: | 10.7507/1001-5515.202401063 |
Abstrakt: | Simulation of the human biological lung is a crucial method for medical professionals to learn and practice the use of new pulmonary interventional diagnostic and therapeutic devices. The study on ventilation effects of the simulation under positive pressure ventilation mode provide valuable guidance for clinical ventilation treatment. This study focused on establishing an electrical simulation ventilation model, which aims to address the complexities in parameter configuration and slow display of air pressure and airflow waveforms in simulating the human biological lung under positive pressure ventilation mode. A simulated ventilation experiment was conducted under pressure-regulated volume control (PRVC) positive pressure ventilation mode, and the resulting ventilation waveform was compared with that of normal adults. The experimental findings indicated that the average error of the main reference index moisture value was 9.8% under PRVC positive pressure ventilation mode, effectively simulating the ventilatory effect observed in normal adults. So the established electrical simulation ventilation model is feasible, and provides a foundation for further research on the simulation of human biological lung positive pressure ventilation experimental platform. |
Databáze: | MEDLINE |
Externí odkaz: |