A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study.
Autor: | Kaneko S; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan. s-kaneko@nagasaki-u.ac.jp., Makino M; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Kawazoe Y; Clinical Research Center, Nagasaki University Hospital, Nagasaki, Japan., Sato S; Clinical Research Center, Nagasaki University Hospital, Nagasaki, Japan., Iwamizu A; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Narimatsu R; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Yamaguchi H; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Miyagawa K; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Ichinomiya T; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Murata H; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Yoshitomi O; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan., Hara T; Department of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of anesthesia [J Anesth] 2024 Dec; Vol. 38 (6), pp. 811-820. Date of Electronic Publication: 2024 Aug 31. |
DOI: | 10.1007/s00540-024-03397-3 |
Abstrakt: | Purpose: We evaluated the electromyography (EMG)-based neuromuscular monitoring detectability of our novel stimulating electrode attachment method compared to the original Nihon-Kohden (Tokyo, Japan) attachment method. Methods: This single-center randomized, double-blind, controlled pilot study enrolled 32 patients aged ≥ 18 years, undergoing scheduled laparoscopic surgery. The EMG electrode NM-345Y™ was attached to one forearm using the Nihon-Kohden method (Pattern N-K) and the other forearm using our novel method (Pattern Cross). The allocation to each attachment method was determined post-randomization. In Pattern Cross, the NM-345Y™ was attached such that the line connecting the anode and cathode crosses the ulnar nerve. Patients received 0.9 mg/kg rocuronium after calibration with the forearm in 90-degree supination. Following tracheal intubation, the forearm was positioned in 0-degree pronation. Intraoperatively, 0.2 mg/kg rocuronium was administered if the train-of-four (TOF) count one persisted for 1 min on either side. Post-surgery, the forearm position was returned to 90-degree supination, and rocuronium was antagonized with sugammadex. TOF and post-tetanic count (PTC) were simultaneously measured bilaterally every 15 s and 5 min, respectively, from post-calibration to tracheal extubation. Results: The time to first PTC appearance was significantly shorter by 33 min in the Pattern Cross group than in the Pattern N-K group (95% Confidence interval: 1-66, p = 0.043). Following sugammadex administration, TOF ratios ≥ 0.9 were achieved in 72% of patients in the Pattern N-K group and 97% of those in the Pattern Cross group (p = 0.025). Conclusions: Crossing the line connecting the anode and cathode with the ulnar nerve stabilizes EMG-based neuromuscular monitoring detectability. Competing Interests: Declarations. Conflict of interest: The authors have no conflicts of interest to declare. (© 2024. The Author(s) under exclusive licence to Japanese Society of Anesthesiologists.) |
Databáze: | MEDLINE |
Externí odkaz: |