In vitro assessment of cementation of CAD/CAM fabricated prostheses over titanium bases. A systematic review.

Autor: Ntovas P; Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA., Ladia O; Private Practice, Athens, Greece., Pachiou A; Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece., Fehmer V; Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland., Sailer I; Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
Jazyk: angličtina
Zdroj: Clinical oral implants research [Clin Oral Implants Res] 2024 Oct; Vol. 35 (10), pp. 1203-1225. Date of Electronic Publication: 2024 Aug 27.
DOI: 10.1111/clr.14347
Abstrakt: Objectives: The objective of this study is to investigate the outcomes of clinically relevant laboratory studies regarding the cementation of implant-supported restorations over ti-bases.
Materials and Methods: The present study has been conducted according to PRISMA statement. An electronic search was performed, including publications up to March 2024, to identify studies investigating the parameters affecting the cementation between ti-bases and CAD/CAM prostheses. An assessment of the internal validity was performed, using a custom-made risk of bias tool (QUIN).
Results: From the included studies, 40.1% were reported on luting systems, 25% on ti-base surface treatment, 25% on restoration surface, 21.8% on restoration material, and 18.7% on ti-base height. The majority of the included studies were associated with a medium risk of bias. In the absence of micro-retentive features, air-abrasion of ti-bases with a minimum height of 3.5 mm can be beneficial for restoration's retention. The bonding performance can vary not only between different bonding systems but also for different applications within the same system, based on a restoration's material and surface treatment as well as on ti-base height and surface treatment.
Conclusions: The height of the ti-base seems to be the prevailing factor as it constitutes the prerequisite for other modifications of the bonding surfaces to have an advantageous effect. Since the parameters that can affect bonding performance between ti-base and restoration can interact with each other, it is important for the clinician to focus on verified bonding protocols.
(© 2024 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.)
Databáze: MEDLINE