Enhanced pyrophosphate detection: Utilizing oPD-derived carbon dots and Fe 3+ interactions in a paper strip biosensor.
Autor: | Garg R; Department of Bioengineering and Biotechnology, Birla Institute of Technology, Mesra, Jharkhand, 835215, India., Prasad D; Department of Bioengineering and Biotechnology, Birla Institute of Technology, Mesra, Jharkhand, 835215, India. Electronic address: dinesh@bitmesra.ac.in. |
---|---|
Jazyk: | angličtina |
Zdroj: | Biochemical and biophysical research communications [Biochem Biophys Res Commun] 2024 Dec 20; Vol. 739, pp. 150577. Date of Electronic Publication: 2024 Aug 22. |
DOI: | 10.1016/j.bbrc.2024.150577 |
Abstrakt: | The development of portable, cost-effective, and straightforward DNA biosensors holds immense importance in various fields, including healthcare, environmental monitoring, and food safety. This study contributes to the objective by introducing an innovative approach for synthesizing carbon dots (Cdots) with high quantum yield (QY) and remarkable selectivity for Fe 3+ ions. Utilizing o-phenylenediamine as a precursor, the study achieved a straightforward and environmentally friendly synthesis method, enabling the efficient detachment of metal ions from the Cdot surface upon introducing pyrophosphate (PPi). The presence of surface hydroxyl and amino groups facilitated specific Fe 3+ recognition. Employing D-optimal response surface methodology, the study optimized Cdot synthesis parameters, identifying temperature and heating time as critical factors influencing QY. Statistical analysis confirmed the model's reliability, predicting maximum QY of 48.8 % with minimal deviation from experimental results. Characterization studies revealed the amorphous nature of Cdots through HR-TEM, XRD, and FTIR analysis. Furthermore, the proposed LAMP/PPi biosensing technique demonstrated higher sensitivity, specificity, and repeatability, with negligible interference from common anions and efficacy across varying pH levels. The limit of detection (LOD) of 0.079 (±0.01) μM and the detection range of 0.1 μM-2 mM underscore the biosensor's practical utility. This study highlights a promising direction for developing paper-based LAMP/PPi biosensors with potential diagnostics and environmental monitoring applications. Significantly, the biosensing technique is applicable to any DNA amplification method generating pyrophosphate (PPi) as a by-product. Competing Interests: Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Dinesh Prasad reports financial support was provided by Birla Institute of Technology. DINESH PRASAD reports a relationship with Birla Institute of Technology. (Copyright © 2024 Elsevier Inc. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |