Hyperspectral full-field quick-EXAFS imaging at the ROCK beamline for monitoring micrometre-sized heterogeneity of functional materials under process conditions.

Autor: Briois V; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Itié JP; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Polian A; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., King A; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Traore AS; IPCMS, Strasbourg, France., Marceau E; UCCS Lille, France., Ersen O; IPCMS, Strasbourg, France., La Fontaine C; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Barthe L; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Beauvois A; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Roudenko O; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France., Belin S; Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France.
Jazyk: angličtina
Zdroj: Journal of synchrotron radiation [J Synchrotron Radiat] 2024 Sep 01; Vol. 31 (Pt 5), pp. 1084-1104. Date of Electronic Publication: 2024 Aug 23.
DOI: 10.1107/S1600577524006581
Abstrakt: Full-field transmission X-ray microscopy has been recently implemented at the hard X-ray ROCK-SOLEIL quick-EXAFS beamline, adding micrometre spatial resolution to the second time resolution characterizing the beamline. Benefiting from a beam size versatility due to the beamline focusing optics, full-field hyperspectral XANES imaging has been successfully used at the Fe K-edge for monitoring the pressure-induced spin transition of a 150 µm × 150 µm Fe(o-phen) 2 (NCS) 2 single crystal and the charge of millimetre-sized LiFePO 4 battery electrodes. Hyperspectral imaging over 2000 eV has been reported for the simultaneous monitoring of Fe and Cu speciation changes during activation of a FeCu bimetallic catalyst along a millimetre-sized catalyst bed. Strategies of data acquisition and post-data analysis using Jupyter notebooks and multivariate data analysis are presented, and the gain obtained using full-field hyperspectral quick-EXAFS imaging for studies of functional materials under process conditions in comparison with macroscopic information obtained by non-spatially resolved quick-EXAFS techniques is discussed.
(open access.)
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje