Foreign Body Reaction to Ion-Beam-Treated Polyurethane Implant.

Autor: Chudinov VS; Institute of Continuous Media Mechanics, Ural Branch, Russian Academy of Sciences, Perm 614013, Russia., Shardakov IN; Institute of Continuous Media Mechanics, Ural Branch, Russian Academy of Sciences, Perm 614013, Russia., Litvinov VV; Therapeutic Faculty, Perm State Medical University, Perm 614990, Russia., Solodnikov SY; Applied Chemical and Biochemical Research Center, Perm National Research Polytechnic, Perm 614990, Russia., Chudinova EY; Imbiocom Ltd., Perm 614990, Russia., Kondyurina IV; School of Medicine, University of Sydney, Camperdown, NSW 2050, Australia.; Ewingar Scientific, Ewingar, NSW 2469, Australia., Kondyurin AV; Ewingar Scientific, Ewingar, NSW 2469, Australia.; School of Physics, University of Sydney, Camperdown, NSW 2050, Australia.
Jazyk: angličtina
Zdroj: Materials (Basel, Switzerland) [Materials (Basel)] 2024 Aug 02; Vol. 17 (15). Date of Electronic Publication: 2024 Aug 02.
DOI: 10.3390/ma17153833
Abstrakt: All artificial materials used for implantation into an organism cause a foreign body reaction. This is an obstacle for a number of medical technologies. In this work, we investigated the effect of high-energy ion bombardment on polyurethane for medical purposes and the reaction of body tissues to its insertion into the mouse organism. An analysis of the cellular response and shell thickness near the implant showed a decrease in the foreign body reaction for implants treated with high-energy ions compared to untreated implants. The decrease in the reaction is associated with the activation of the polyurethane surface due to the formation on the surface layer of condensed aromatic clusters with unbonded valences on the carbon atoms at the edges of such clusters and the covalent attachment of the organism's own proteins to the activated surface of the implant. Thus, immune cells do not identify the implant surface coated with its own proteins as a foreign body. The deactivation of free valences at the edges of aromatic structures due to the storage of the treated implant before surgery reduces surface activity and partially restores the foreign body response. For the greatest effect in eliminating a foreign body reaction, it is recommended to perform the operation immediately after treating the implant with high-energy ions, with minimal contact of the treated surface with any materials.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje