Collagen imaging reveals synergistic effects of sutures and host-donor misalignment on topographical irregularities in penetrating keratoplasty.

Autor: Gururani H; Department of Mechanical and Aerospace Engineering, Micro-Mechanics Lab, Indian Institute of Technology Hyderabad, Sangareddy, Telangana, India., Chittajallu SNSH; Department of Mechanical and Aerospace Engineering, Micro-Mechanics Lab, Indian Institute of Technology Hyderabad, Sangareddy, Telangana, India., Doulatramani M; The Cornea Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India., Chinthapenta V; Department of Mechanical and Aerospace Engineering, Micro-Mechanics Lab, Indian Institute of Technology Hyderabad, Sangareddy, Telangana, India., Basu S; Professor Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, Telangana, India.; The Cornea Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India., M R; Department of Mechanical and Aerospace Engineering, Engineering Optics Lab, Indian Institute of Technology Hyderabad, Sangareddy, Telangana, India.
Jazyk: angličtina
Zdroj: PloS one [PLoS One] 2024 Aug 08; Vol. 19 (8), pp. e0308204. Date of Electronic Publication: 2024 Aug 08 (Print Publication: 2024).
DOI: 10.1371/journal.pone.0308204
Abstrakt: Purpose: Mitigating unwanted refractive errors is crucial for surgeons to ensure quality vision after penetrating keratoplasty (PK). The primary objective of the present study is to highlight the importance of microstructural matching of the host and the donor cornea during PK on the distribution of the corneal tissue while suturing.
Methods: For this purpose, the present study undertakes an in-vitro PK model to analyse the effect of suturing and host-donor misalignment on corneal birefringence. Five groups of experiments were performed using five corneoscleral buttons. In each group, N = 16 data points (corresponding to 16 simple interrupted sutures) were assessed before and after PK with five degrees of misalignments, 0°, 30°, 45°, 60° and 90° to detect the variations in corneal birefringence post-PK. The technique of digital photoelasticity is utilized to capture the corneal birefringence experimentally.
Results: The local and global features of corneal birefringence provided interesting insights into the nuances of corneal birefringence in PK. Statistical analysis was performed to study the effects of suturing on the birefringence around the suture bites. It was observed that the interaction of the suture tension and structural misalignment between the host and the donor cornea influences the corneal birefringence in PK. Conclusions The zero-degree structural misalignment of the host and the donor tissue is preferable to minimize the topographical irregularities and related astigmatism post-PK. The findings of the present study envisage an additional step of structurally aligning the donor tissue with the host before suturing to minimize topographical irregularities in PK.
Competing Interests: NO authors have competing interests
(Copyright: © 2024 Gururani et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)
Databáze: MEDLINE