Autor: |
Zhang Y; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao 266042, PR China., Li Z; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao 266042, PR China., Du J; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao 266042, PR China., Jie G; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao 266042, PR China., Zhou H; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao 266042, PR China. |
Jazyk: |
angličtina |
Zdroj: |
Analytical chemistry [Anal Chem] 2024 Aug 20; Vol. 96 (33), pp. 13690-13698. Date of Electronic Publication: 2024 Aug 06. |
DOI: |
10.1021/acs.analchem.4c02674 |
Abstrakt: |
BRCA1 gene and carcinoembryonic antigen (CEA) are important markers of breast cancer, so accurate detection of them is significant for early detection and diagnosis of breast cancer. In this study, a potential-resolved ratio electrochemiluminescence (ECL) biosensor using perylene diimide (PDI)-metal-organic framework and DNA nanoflowers (NFs)-CdS quantum dots (QDs) was constructed for detection of BRCA1 and CEA. Specifically, PDI-MOF and CdS QDs can generate potential-resolved intense ECL signals only using one coreactant, so the detection procedure can be effectively simplified. PDI-MOF was first attached to the electrode by graphene oxide, and the dopamine (DA) probe was linked to quench the ECL signal by DNA hybridization. In the presence of target BRCA1, it can form a bipedal DNA walker, so the quenching molecules (DA) were detached from the electrode via the walker amplification process aided by Mg 2+ , so that the PDI signal at -0.25 V was restored for the BRCA1 assay. Moreover, CdS QDs@DNA NFs as amplified signal probes were formed by self-assembly, and the target CEA-amplified product introduced the CdS QDs@DNA NFs to the electrode, so the QD ECL signal at -1.42 V was enhanced, while the ECL signal of PDI is unchanged; thus, CEA detection was achieved by the ratio value between them. Therefore, the detection accuracy is guaranteed by detection of two cancer markers and a ratio value. This biosensor has a great contribution to the development of new ECL materials and a novel ECL technique for fast and efficient multitarget assays, showing great significance for the early monitoring and diagnosis of breast cancer. |
Databáze: |
MEDLINE |
Externí odkaz: |
|