Complications of Hardware Removal in Pediatric Orthopaedic Surgery.

Autor: Desai VM; Department of Orthopaedics, The Children's Hospital of Philadelphia, Philadelphia, PA., Mahon SJ, Pang A, Hauth L, Shah AS, Anari JB
Jazyk: angličtina
Zdroj: Journal of pediatric orthopedics [J Pediatr Orthop] 2024 Nov-Dec 01; Vol. 44 (10), pp. e957-e964. Date of Electronic Publication: 2024 Aug 01.
DOI: 10.1097/BPO.0000000000002780
Abstrakt: Background: Hardware removal (HR) is one of the most common surgical procedures in pediatric orthopaedics. Surgeons advocate for HR for a variety of reasons, including to limit peri-implant fracture risk, restore native anatomy for adult reconstruction surgery, permit bone growth and development, and mitigate implant-related pain/irritation. To our knowledge, no recent study has investigated the characteristics and complications of HR in pediatric orthopaedics. The goal of this study is to report the prevalence and complications of hardware removals across all of pediatric orthopaedic surgery.
Methods: A retrospective case series was conducted of all hardware removals from 2012 to 2023 performed at a single urban tertiary-care children's hospital. Cases were identified using CPT codes/billing records. Spinal hardware and cases for which hardware was either implanted or explanted at an outside hospital were excluded. Patient demographic and clinical data were recorded. For patients with multiple hardware removals, each case was recorded independently.
Results: A total of 2585 HR cases for 2176 children met study criteria (57.7% male; mean age 12.3±4.4 y). The median postoperative follow-up time was 1.7 months (interquartile range: 0.6 to 6.9). The most common sites of hardware removal were the femur/knee (32.7%), tibia/fibula/ankle (19.3%), and pelvis/hip (18.5%). The most common complications included sustained, new-onset postoperative pain (2.6%), incomplete hardware removal (1.6%), and perioperative fracture (1.4%). The overall complication rate of hardware removal was 9.5%. Eighty-eight percent of patients who underwent hardware removal for pain experienced pain relief postoperatively. HR >18 months after insertion had a 1.2x higher odds of overall complication ( P =0.002) and 3x higher odds of incomplete removal/breakage ( P <0.001) than hardware removed 9 to 18 months after insertion.
Conclusions: The overall complication rate of hardware removal across a large series in the pediatric population was 9.5%. Despite hardware removal being one of the most common and often routine procedures in pediatric orthopaedics, the complication rate is not benign. Surgeons should inform patients and families about the likelihood of success and the risks of incomplete removal during the informed consent process.
Level of Evidence: IV.
Competing Interests: J.B.A. is a consultant for DePuy Synthes. The other authors declare no conflicts of interest.
(Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)
Databáze: MEDLINE