A novel disposable ultrasensitive sensor based on nanosized ceria uniformly loaded carbon nanofiber nanoceramic film wrapped on pencil graphite rods for electrocatalytic monitoring of a tyrosine kinase inhibitor capmatinib.

Autor: Alanazi AZ; Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia., Alhazzani K; Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia., El-Wekil MM; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut, Egypt., Ali ABH; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut, Egypt., Darweesh M; Department of Medical Biochemistry and Microbiology, Uppsala University, Uppsala, Sweden., Ibrahim H; Department of Chemistry, Faculty of Science, Assiut University, Assiut, 71516, Egypt; School of Biotechnology, Badr University in Assiut, Assiut, 2014101, Egypt. Electronic address: Hossieny.Ibrahim@aun.edu.eg.
Jazyk: angličtina
Zdroj: Talanta [Talanta] 2024 Nov 01; Vol. 279, pp. 126610. Date of Electronic Publication: 2024 Jul 24.
DOI: 10.1016/j.talanta.2024.126610
Abstrakt: For the first time, we introduce a novel disposable and ultrasensitive sensing electrode made up of nanosized ceria uniformly loaded carbon nanofibers (CeNPs@CNF) sol-gel nanoceramic film (CF) wrapped on eco-friendly and inexpensive pencil graphite rods (PGRs) to explore their electro-catalytic detection of the anticancer drug capmatinib (CMB). The as-prepared CeNPs@CNF hybrid nanocomposite was described by XRD, SEM, TEM, HRTEM, and EDX analysis. The CV study clearly demonstrated that, the disposable CeNPs@CNF-CF/PGRE sensor exhibited excellent redox activities in the ideal probe [Fe(CN) 6 ] 3-/4- . Due to the outstanding electrochemical properties, larger electrochemically active surface area, and tremendous electro-catalytic activity of CeNPs@CNF, the reduction current of CMB on the CeNPs@CNF-CF/PGRE sensor is considerably higher than that of bare PGRE. The detection conditions, such as supporting electrolyte, pH of the buffer solution, amount of modifier, adsorption potential, and time, were studied and optimized. The sensing platform demonstrated high sensitivity (1.2 μA nM -1  cm -2 ), an ultralow detection limit (0.6 nM), and a wide linear range of 2.0 nM-400 nM of CMB compared to the bare PGRE. Additionally, the CeNPs@CNF-CF/PGRE sensor showed high selectivity, stability, and simple operation, which provided a promising alternative tool for fast detection of CMB in human body fluids with good recoveries.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2024 Elsevier B.V. All rights reserved.)