Real-time quantification of laser speckle contrast imaging during intestinal laparoscopic surgery: successful demonstration in a porcine intestinal ischemia model.
Autor: | Hoffman JT; Faculty Campus Fryslân, University of Groningen, Wirdumerdijk 34, 8911 CE, Leeuwarden, The Netherlands. tim.hoffman@limis.com.; University Medical Centre Groningen, Optical Molecular Imaging Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. tim.hoffman@limis.com.; Department of Surgery, Medical Centre Leeuwarden, Henri Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands. tim.hoffman@limis.com.; LIMIS Development, Henri Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands. tim.hoffman@limis.com., Heuvelings DJI; NUTRIM, Research Institute of Nutrition and Translational Research in Metabolism, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.; Department of Surgery, Maastricht University Medical Centre+, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands., van Zutphen T; Faculty Campus Fryslân, University of Groningen, Wirdumerdijk 34, 8911 CE, Leeuwarden, The Netherlands., Stassen LPS; NUTRIM, Research Institute of Nutrition and Translational Research in Metabolism, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.; Department of Surgery, Maastricht University Medical Centre+, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands., Kruijff S; Department of Surgery, University Medical Centre Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.; Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands.; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solnavägen 1, Solna, 171 77, Stockholm, Sweden., Boerma EC; Faculty Campus Fryslân, University of Groningen, Wirdumerdijk 34, 8911 CE, Leeuwarden, The Netherlands., Bouvy ND; Department of Surgery, Maastricht University Medical Centre+, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands.; GROW School for Oncology and Developmental Biology, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands., Heeman WT; University Medical Centre Groningen, Optical Molecular Imaging Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.; Department of Surgery, Medical Centre Leeuwarden, Henri Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands.; LIMIS Development, Henri Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands., Al-Taher M; Department of Surgery, Maastricht University Medical Centre+, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands. |
---|---|
Jazyk: | angličtina |
Zdroj: | Surgical endoscopy [Surg Endosc] 2024 Sep; Vol. 38 (9), pp. 5292-5303. Date of Electronic Publication: 2024 Jul 17. |
DOI: | 10.1007/s00464-024-11076-3 |
Abstrakt: | Background: Anastomotic leakage (AL) is a dreaded complication following colorectal cancer surgery, impacting patient outcome and leads to increasing healthcare consumption as well as economic burden. Bowel perfusion is a significant modifiable factor for anastomotic healing and thus crucial for reducing AL. Aims: The study aimed to calculate a cut-off value for quantified laser speckle perfusion units (LSPUs) in order to differentiate between ischemic and well-perfused tissue and to assess inter-observer reliability. Methods: LSCI was performed using a porcine ischemic small bowel loop model with the PerfusiX-Imaging® system. An ischemic area, a well-perfused area, and watershed areas, were selected based on the LSCI colormap. Subsequently, local capillary lactate (LCL) levels were measured. A logarithmic curve estimation tested the correlation between LSPU and LCL levels. A cut-off value for LSPU and lactate was calculated, based on anatomically ischemic and well-perfused tissue. Inter-observer variability analysis was performed with 10 observers. Results: Directly after ligation of the mesenteric arteries, differences in LSPU values between ischemic and well-perfused tissue were significant (p < 0.001) and increased significantly throughout all following measurements. LCL levels were significantly different (p < 0.001) at both 60 and 120 min. Logarithmic curve estimation showed an R 2 value of 0.56 between LSPU and LCL values. A LSPU cut-off value was determined at 69, with a sensitivity of 0.94 and specificity of 0.87. A LCL cut-off value of 3.8 mmol/L was found, with a sensitivity and specificity of 0.97 and 1.0, respectively. There was no difference in assessment between experienced and unexperienced observers. Cohen's Kappa values were moderate to good (0.52-0.66). Conclusion: Real-time quantification of LSPUs may be a feasible intraoperative method to assess tissue perfusion and a cut-off value could be determined with high sensitivity and specificity. Inter-observer variability was moderate to good, irrespective of prior experience with the technique. (© 2024. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: |