A meta-analysis comparing the performance of narrowband CE-Chirp and 500 Hz tone burst stimuli in recording cervical vestibular evoked myogenic potential (cVEMP).
Autor: | Zakaria MN; Audiology Programme, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia., Abdallatif AMR; Audiology Programme, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia., Wan Mohamad WN; Audiology Programme, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia., Rashid MFN; Audiology Programme, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia., Patuzzi R; Audiology Programme, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia., Abdullah B; Department of Otorhinolaryngology, School of Medical Sciences, Universiti Sains Malaysia, 16150, Kubang Kerian, Kelantan, Malaysia., Salim R; Department of Otorhinolaryngology, School of Medical Sciences, Universiti Sains Malaysia, 16150, Kubang Kerian, Kelantan, Malaysia. rosdan@usm.my., Omar M; Centre for Rehabilitation and Special Needs Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia. |
---|---|
Jazyk: | angličtina |
Zdroj: | Scientific reports [Sci Rep] 2024 Jun 26; Vol. 14 (1), pp. 14707. Date of Electronic Publication: 2024 Jun 26. |
DOI: | 10.1038/s41598-024-64402-z |
Abstrakt: | Due to contradictory outcomes in the literature, the aim of this meta-analysis is to verify whether the narrowband (NB) CE-Chirp stimulus (centred at 500 Hz) would produce more robust cervical vestibular evoked myogenic potential (cVEMP) responses relative to the conventional 500 Hz tone burst. The literature search was conducted using PubMed, Scopus, and Web of Science databases and the terms used were "vestibular evoked myogenic potential" and "chirp". The cVEMP parameters to be analysed were P1 latency, N1 latency, and P1-N1 amplitude. A total of 59 potential articles were obtained from the database search. Eventually, five articles were found to be eligible for the meta-analysis (with n = 222). As found, P1 and N1 latencies of cVEMP were significantly shorter for the chirp stimulus (p < 0.001), with substantially large effect sizes. On the other hand, P1-N1 amplitude values were found to be not statistically different between the two stimuli (p = 0.189), with a small effect size. It appears that there is no indication to support the superiority of the NB CE-Chirp stimulus (centred at 500 Hz) in the cVEMP testing (relative to the conventional 500 Hz tone burst). In particular, both stimuli produce comparable P1-N1 amplitude values. Even though P1 and N1 latencies are statistically shorter for the chirp stimulus, this may not reflect that it should be the preferred stimulus for recording cVEMP responses (and the reasons for this are discussed accordingly). (© 2024. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: |