Introducing AEM-RADS: A novel reporting and data system for abdominal emergencies.

Autor: Erdemir AG; Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara, Turkey. a.gurkan.erdemir@gmail.com., Başaran H; Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara, Turkey., İdilman İS; Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara, Turkey., Onur MR; Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara, Turkey., Akpınar E; Department of Radiology, Biological Sciences Division, The University of Chicago, Chicago, USA.
Jazyk: angličtina
Zdroj: Abdominal radiology (New York) [Abdom Radiol (NY)] 2024 Nov; Vol. 49 (11), pp. 4175-4184. Date of Electronic Publication: 2024 Jun 25.
DOI: 10.1007/s00261-024-04453-y
Abstrakt: Purpose: The Reporting and Data System (RADS) has proven successful in various medical settings, but a standardized reporting system for abdominal emergencies is lacking. In this study, the Abdominal Emergency Reporting and Data System (AEM-RADS) for urgent findings on abdominal CT scans is introduced to address the need for consistency in emergency radiology.
Methods: In this prospective observational study, conducted over a six-month period, the urgency of abdominal CT scans was assessed using the proposed AEM-RADS scoring system. The committee developed a scale ranging from AEM-RADS 1 (normal) to AEM-RADS 5 (urgent disease). Interobserver agreement between two observers with different experience was evaluated, and robust AEM-RADS reference values were established by radiologists who were not observers. Statistical analysis used mean, standard deviations and Kendall's tau analysis for interobserver agreement.
Results: Among 2656 patients who underwent CT for abdominal emergencies, the AEM-RADS distribution was 17.50% AEM-RADS 1, 28.57% AEM-RADS 2, 7.22% AEM-RADS 3, 35.61% AEM-RADS 4, and 11.06% AEM-RADS 5. Interobserver agreement was high, especially for urgent and emergent cases (p < 0.0001). Notable discrepancies were observed in AEM-RADS categories 2C-D and 3B-C, emphasizing the influence of radiologists' experience on interpretation. However, the interobserver agreement for both AEM-RADS 2C-D and 3B-C were statistically significant (p < 0.001).
Conclusions: AEM-RADS showed promising reliability, particularly in identifying urgent and emergent cases. Despite some inter-observer discrepancies, the system showed potential for standardized emergency workups. AEM-RADS could significantly enhance diagnostic accuracy in abdominal emergencies and provide a structured framework for shared decision-making between clinicians and radiologists.0.
(© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)