Rapid and Comprehensive Screening for Urogenital and Gastrointestinal Schistosomiasis with Handheld Digital Microscopy Combined with Circulating Cathodic Antigen Testing.

Autor: Coulibaly JT; Unité de Formation et de Recherche Biosciences, Université Félix Houphouët-Boigny, Abidjan, Côte d'Ivoire.; Centre Suisse de Recherches Scientifiques en Côte d'Ivoire, Abidjan, Côte d'Ivoire., Silue KD; Unité de Formation et de Recherche Biosciences, Université Félix Houphouët-Boigny, Abidjan, Côte d'Ivoire.; Centre Suisse de Recherches Scientifiques en Côte d'Ivoire, Abidjan, Côte d'Ivoire., de León Derby MD; Department of Bioengineering, University of California, Berkeley, Berkeley, California., Fletcher DA; Department of Bioengineering, University of California, Berkeley, Berkeley, California.; Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, California.; Chan Zuckerberg Biohub, San Francisco, California., Fisher KN; Division of General Internal Medicine, Toronto General Hospital, University Health Network, Toronto, Canada.; Division of Infectious Diseases, Toronto General Hospital, University Health Network, Toronto, Canada., Andrews JR; Division of Infectious Diseases and Geographic Medicine, Stanford University School of Medicine, Stanford, California., Bogoch II; Division of General Internal Medicine, Toronto General Hospital, University Health Network, Toronto, Canada.; Division of Infectious Diseases, Toronto General Hospital, University Health Network, Toronto, Canada.; Department of Medicine, University of Toronto, Toronto, Canada.
Jazyk: angličtina
Zdroj: The American journal of tropical medicine and hygiene [Am J Trop Med Hyg] 2024 Jun 11; Vol. 111 (2), pp. 387-390. Date of Electronic Publication: 2024 Jun 11 (Print Publication: 2024).
DOI: 10.4269/ajtmh.24-0043
Abstrakt: Novel methods are required to aid the monitoring of schistosomiasis control and elimination initiatives through mass drug administration. Portable digital and mobile phone microscopy is a promising tool for this purpose. This cross-sectional study evaluated the diagnostic operating characteristics of a converted mobile phone microscope (the SchistoScope) for the detection of Schistosoma haematobium eggs, as determined by community-based field workers and expert microscopists, compared with a field gold standard of light microscopy. Three hundred sixty-five urine samples were evaluated by conventional light microscopy, with 49 (13.4%) positive for S. haematobium. Compared with light microscopy, the sensitivity and specificity of S. haematobium detection by field microscopists trained to use the SchistoScope were 26.5% (95% CI: 14.9-41.1%) and 98.4% (95% CI: 96.3-99.5%), respectively. The sensitivity and specificity of S. haematobium detection by expert microscopists using the SchistoScope was 74% (95% CI: 59.7-85.4%) and 98.1% (95% CI: 95.9-99.3%), respectively, compared with light microscopy. The sensitivity rose to 96.1% and 100% when evaluating for egg counts greater than five and 10 eggs per 10 mL, respectively. A point-of-care circulating cathodic anion (POC CCA) test was used to evaluate Schistosoma mansoni; however, there were too few positive samples to reliably comment on diagnostic characteristics. This study demonstrated that a "urine-only" approach to rapidly screen for schistosomiasis at the point of sample collection can be conducted with mobile phone microscopy (S. haematobium) coupled with POC CCA (S. mansoni). Such an approach may aid in streamlined schistosomiasis control and elimination initiatives.
Databáze: MEDLINE