B 0 -insensitive image navigators for prospective motion-corrected MRS with localized second-order shimming.

Autor: Adanyeguh IM; Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA., Park YW; Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA., Henry PG; Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA., Deelchand DK; Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA.
Jazyk: angličtina
Zdroj: Magnetic resonance in medicine [Magn Reson Med] 2024 Oct; Vol. 92 (4), pp. 1338-1347. Date of Electronic Publication: 2024 May 05.
DOI: 10.1002/mrm.30151
Abstrakt: Purpose: Localized shimming in single-voxel MRS often results in large B 0 inhomogeneity outside the volume-of-interest. This causes unacceptable degradation in motion navigator images. Switching back and forth between whole-brain shim and localized shim is possible for linear shims, but not for higher-order shims. Here we propose motion navigators largely insensitive to B 0 inhomogeneity for prospective motion-corrected MRS with localized higher-order shimming.
Methods: A recent fast high-resolution motion navigator based on spiral-in/out k-space trajectories and multislice-to-volume registration was modified by splitting the readout into multiple shot interleaves which shortened the echo time and reduced the effect of B 0 inhomogeneity. The performance of motion correction was assessed in healthy subjects in the prefrontal cortex using a sLASER sequence at 3T (N = 5) and 7T (N = 5).
Results: With multiple spatial interleaves, excellent quality navigator images were acquired in the whole brain in spite of large B 0 inhomogeneity outside the MRS voxel. The total duration of the navigator in sLASER remained relatively short even with multiple shots (3T: 10 spatial interleaves 94 ms per slice; 7T: 15 spatial interleaves 103 ms per slice). Prospective motion correction using the multi-shot navigators yielded comparable spectral quality (water linewidth and metabolite SNR) with and without subject motion.
Conclusion: B 0 -insensitive motion navigators enable prospective motion correction for MRS with all first- and second-order shims adjusted in the MRS voxel, providing optimal spectral linewidth.
(© 2024 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
Databáze: MEDLINE