NiFe-LDH/nylon 6 composite electrospun on polypropylene membrane: A new extractive device development for porous membrane protected micro-solid-phase extraction of organophosphate pesticides from fresh fruit juice samples coupled with liquid chromatography tandem mass analysis.

Autor: Shirkhodaie M; School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran., Seidi S; Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran. Electronic address: s.seidi@kntu.ac.ir., Shemirani F; School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran. Electronic address: fashemirani@ut.ac.ir., Moghadasian S; Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran.
Jazyk: angličtina
Zdroj: Food chemistry [Food Chem] 2024 Sep 01; Vol. 451, pp. 139368. Date of Electronic Publication: 2024 Apr 16.
DOI: 10.1016/j.foodchem.2024.139368
Abstrakt: A unique strategy for developing porous membrane protected micro-solid phase extraction has been provided. An electrospun composite was fabricated on the sheet of membrane. To this end, NiFe-layered double hydroxide/Nylon 6 composite nanofibers were coated on a polypropylene membrane sheet followed by folding into a pocket shape, which were then utilized as a novel extractive device to extract of organophosphorus pesticides from fresh fruit juice samples prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. The fabricated hybrid composites were successfully characterized. The effective parameters on extraction performance were investigated. LODs were 0.020-0.065 ng mL -1 . Excellent linearity (R 2 ≥0.996) was observed between 0.05 and 100.0 ng mL -1 . RSDs% were in the range of 3.1-5.8% (intra-day, n = 3) and 2.6-5.5% (inter-day, n = 3×3). Satisfactory related recovery values within the acceptable range of 90.7-111.2% with RSDs% below 6.7% were achieved for the analysis of real samples.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2024 Elsevier Ltd. All rights reserved.)
Databáze: MEDLINE