Performance Evaluation of a New Sport Watch in Sleep Tracking: A Comparison against Overnight Polysomnography in Young Adults.

Autor: Parent AA; Department of Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Libin Cardiovascular Institute of Alberta, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada., Guadagni V; Department of Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada., Rawling JM; Department of Family Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada., Poulin MJ; Department of Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Libin Cardiovascular Institute of Alberta, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.; Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada.; O'Brien Institute of Public Health, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada.
Jazyk: angličtina
Zdroj: Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Mar 30; Vol. 24 (7). Date of Electronic Publication: 2024 Mar 30.
DOI: 10.3390/s24072218
Abstrakt: Introduction : This study aimed to validate the ability of a prototype sport watch (Polar Electro Oy, FI) to recognize wake and sleep states in two trials with and without an interval training session (IT) 6 h prior to bedtime. Methods : Thirty-six participants completed this study. Participants performed a maximal aerobic test and three polysomnography (PSG) assessments. The first night served as a device familiarization night and to screen for sleep apnea. The second and third in-home PSG assessments were counterbalanced with/without IT. Accuracy and agreement in detecting sleep stages were calculated between PSG and the prototype. Results : Accuracy for the different sleep stages (REM, N1 and N2, N3, and awake) as a true positive for the nights without exercise was 84 ± 5%, 64 ± 6%, 81 ± 6%, and 91 ± 6%, respectively, and for the nights with exercise was 83 ± 7%, 63 ± 8%, 80 ± 7%, and 92 ± 6%, respectively. The agreement for the sleep night without exercise was 60.1 ± 8.1%, k = 0.39 ± 0.1, and with exercise was 59.2 ± 9.8%, k = 0.36 ± 0.1. No significant differences were observed between nights or between the sexes. Conclusion : The prototype showed better or similar accuracy and agreement to wrist-worn consumer products on the market for the detection of sleep stages with healthy adults. However, further investigations will need to be conducted with other populations.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje