Effect of Ceramic Thickness on the Bond Strength to Resin-Luting Agents before and after Thermal Cycling.

Autor: Souza CR; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil., Costa AR; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil.; Department of Orthodontics, Graduate Program in Orthodontics - UNIARARAS, Universidade de Araras, SP, Brazil., Borges LPS; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil., Ferraz AGB; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil., Consani RLX; Department of Prosthodontics and Periodontology, Division of Complete Denture, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil., Pacheco RR; Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, GA, USA., Correr AB; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil., Correr-Sobrinho L; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil.
Jazyk: angličtina
Zdroj: Brazilian dental journal [Braz Dent J] 2024 Mar 22; Vol. 35, pp. e245619. Date of Electronic Publication: 2024 Mar 22 (Print Publication: 2024).
DOI: 10.1590/0103-6440202405619
Abstrakt: This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.
Databáze: MEDLINE