Mechanical properties of ion-releasing restorative materials.
Autor: | Lalovic M; Faculty of Stomatology in Pancevo, University Business Academy in Novi Sad, Pancevo, Serbia, marija.lalovic@sfp.rs., Kolak V; Faculty of Stomatology in Pancevo, University Business Academy in Novi Sad, Pancevo, Serbia., Melih I; Faculty of Stomatology in Pancevo, University Business Academy in Novi Sad, Pancevo, Serbia., Nikitovic A; Faculty of Stomatology in Pancevo, University Business Academy in Novi Sad, Pancevo, Serbia., Trajkovic I; Innovation Center of Faculty of Mechanical Engineering in Belgrade, Serbia., Milosevic M; Innovation Center of Faculty of Mechanical Engineering in Belgrade, Serbia., Pejanovic D; Faculty of Stomatology in Pancevo, University Business Academy in Novi Sad, Pancevo, Serbia., Pesic D; Faculty of Stomatology in Pancevo, University Business Academy in Novi Sad, Pancevo, Serbia. |
---|---|
Jazyk: | angličtina |
Zdroj: | American journal of dentistry [Am J Dent] 2024 Feb; Vol. 37 (1), pp. 13-18. |
Abstrakt: | Purpose: To evaluate and compare the laboratory compressive strength (CS), flexural strength (FS), and diametral tensile strength (DTS) of Cention Forte and three bulk fill restorative materials. Methods: A total of 168 specimens were prepared following the manufacturers' instructions and standards for testing CS, FS, and DTS. Mechanical properties of Cention Forte (LC-Cent) were compared to three commercial bulk-fill materials for posterior restorations: Fuji IX Extra (Fuji), Tetric PowerFill (TPF), and Equia Forte HT (Equia). The tests were performed 24 hours after storage in distilled water on a universal testing machine at a crosshead speed of 0.75 mm/minute. Strength values (MPa) were calculated and statistically analyzed by one-way ANOVA and Tukey's post hoc test (P< 0.05). Results: Analysis showed significant differences between tested materials for CS, FS, and DTS (P= 0.0001). LC-Cent showed the highest mean value for FS (112.8 MPa) with a significant difference compared to Fuji and Equia. DTS (49.2 MPa) of LC-Cent was significantly higher than all tested materials. TPF showed the highest mean value (180 MPa) for CS but without significant difference compared to LC-Cent. Clinical Significance: Ion-releasing material Cention Forte, according to obtained results, may serve as a viable alternative for posterior restorations compared to conventional bulk-fill restorative materials. Competing Interests: The authors declare no conflict of interest. The authors acknowledge the support from the Ministry of Education, Science and Technological Development of the Republic of Serbia, Contract no.: 451-03-68/2022-14/200105. (Copyright©American Journal of Dentistry.) |
Databáze: | MEDLINE |
Externí odkaz: |