Optical and aberrometric evaluation of a new enhanced monofocal intraocular lens with isofocal optic design.
Autor: | Pérez-Sanz L; Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.; Miranza IOA, Madrid, Spain., Charbel C; Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain., Poyales F; Miranza IOA, Madrid, Spain., Garzón N; Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain. |
---|---|
Jazyk: | angličtina |
Zdroj: | Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) [Ophthalmic Physiol Opt] 2024 May; Vol. 44 (3), pp. 584-592. Date of Electronic Publication: 2024 Feb 13. |
DOI: | 10.1111/opo.13287 |
Abstrakt: | Purpose: To evaluate the optical and aberrometric outcomes of an enhanced monofocal intraocular lens (ISOPure) compared with those of a standard monofocal lens (MicroPure) having the same platform and material. Methods: A prospective, comparative and randomised clinical study. A total of 28 eyes of 28 patients were randomly assigned to either group. Monocular visual acuity (VA) was measured at distance and intermediate under photopic and mesopic conditions. Aberrometry was analysed for 3.0-, 4.0-, 4.5- and 5.0 mm pupils. The contrast sensitivity defocus curve was measured for 3.0- and 4.5-mm pupils, while the modulation transfer function (MTF) and Strehl ratio (SR) were assessed with a double-pass system. All measurements were performed monocularly 3 months after surgery. Results: No significant differences were found for distance VA. Under photopic conditions, intermediate VA was better with the ISOPure lens, while no significant differences were found between the lenses under mesopic conditions. Internal and total aberrations were higher for the ISOPure lens. No significant differences were found for corneal aberrations. Additionally, both the contrast sensitivity defocus curve and optical quality showed similar behaviour for each lens, with the MTF cut-off frequency exceeding 30 c/deg in both cases. Conclusion: The isofocal ISOPure lens enhanced intermediate VA without affecting distance VA under photopic conditions. Moreover, there were no significant differences in visual quality between the ISOPure and MicroPure lenses, despite the former exhibiting higher internal and total aberrations than the monofocal model. (© 2024 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.) |
Databáze: | MEDLINE |
Externí odkaz: |