Body CT examinations in oncologic patients: the impact of subspecialty radiology on radiation exposure in the clinical practice. A quality care study.

Autor: Rizzo S; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland. stefania.rizzo@eoc.ch.; Faculty of Biomedical Sciences, Università Della Svizzera Italiana (USI), Via G. Buffi 13, 6904, Lugano, Switzerland. stefania.rizzo@eoc.ch., Bellesi L; Service of Medical Physics, Maging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Bellinzona, Switzerland., D'Ermo A; Service of Process Organization and Information, EOC, Support Area, Via Lugano 4D, 6500, Bellinzona, Switzerland., Bonomo L; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., D'Ecclesiis O; Department of Experimental Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy., Magoga F; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Presilla S; Service of Medical Physics, Maging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Bellinzona, Switzerland., Spanò A; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Minzolini V; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Lo Piccolo F; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Heinkel J; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Rezzonico E; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Del Grande M; Oncology Institute of Southern Switzerland, EOC, Bellinzona, Switzerland., Merli M; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland., Del Grande F; Clinic of Radiology, Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), Via Tesserete 46, 6900, Lugano, Switzerland.; Faculty of Biomedical Sciences, Università Della Svizzera Italiana (USI), Via G. Buffi 13, 6904, Lugano, Switzerland.
Jazyk: angličtina
Zdroj: La Radiologia medica [Radiol Med] 2024 Mar; Vol. 129 (3), pp. 429-438. Date of Electronic Publication: 2024 Feb 11.
DOI: 10.1007/s11547-024-01790-2
Abstrakt: Purposes: The primary objective of this retrospective study was to assess whether the CT dose delivered to oncologic patients was different in a subspecialty radiology department, compared to a general radiology department. The secondary explorative objective was to assess whether the objective image quality of CT examinations was different in the two settings.
Materials and Methods: Chest and abdomen CT scans performed for oncologic indications were selected from a general radiology department and a subspecialty radiology department. By using a radiation dose management platform, we extracted and compared CT dose index (CTDI vol ) and dose length product (DLP) both for each phase and for the entire CT exams. For objective image quality evaluation, we calculated the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) at the level of the liver and of the aorta. A P-value < 0.05 was considered significant.
Results: A total of 7098 CT examinations were included. CTDI vol was evaluated in 12,804 phases; DLP in 10,713 phases and in 6714 examinations. The CTDI vol and DLP overall were significantly lower in the subspecialty radiology department compared to the general radiology department CTDI median (IQR) 5.19 (3.91-7.00) and 5.51 (4.17-7.72), DLP median and IQR of 490.0 (342.4-710.6) and 503.4 (359.9-728.8), p < 0.001 and p = 0.01, respectively. The objective image quality showed no significant difference in the general and subspecialty radiology departments, with median and IQR of 4.03 (2.82-5.51) and 3.84 (3.09-4.94) for SNR Liv (p = 0.58); 4.81 (2.70-7.62) and 4.34 (3.05-6.25) for SNR Ao (p = 0.30); 0.83 (0.20-1.89) and 1.00 (0.35-1.57) for CNR Liv (p = 0.99); 2.23 (0.09-3.83) and 1.01 (0.15-2.84) for CNR Ao (p = 0.24) with SNR Liv (p = 0.58), SNR Ao (p = 0.30), CNR Liv (p = 0.99) and CNR Ao (p = 0.24).
Conclusion: In a subspecialty radiology department, CT protocols are optimized compared to a general radiology department leading to lower doses to oncologic patients without significant objective image quality degradation.
(© 2024. The Author(s).)
Databáze: MEDLINE