Response to spontaneous and induced His refractory ventricular premature beats during long RP tachycardia: What is the mechanism?
Autor: | Kakarla S; Division of Cardiac Electrophysiology Sree Chitra Tirunal Institute for Medical Sciences and Technology Thiruvananthapuram India., Abhilash SP; Division of Cardiac Electrophysiology Sree Chitra Tirunal Institute for Medical Sciences and Technology Thiruvananthapuram India., Vijay J; Division of Cardiac Electrophysiology Sree Chitra Tirunal Institute for Medical Sciences and Technology Thiruvananthapuram India., Namboodiri N; Division of Cardiac Electrophysiology Sree Chitra Tirunal Institute for Medical Sciences and Technology Thiruvananthapuram India. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of arrhythmia [J Arrhythm] 2023 Nov 23; Vol. 40 (1), pp. 148-149. Date of Electronic Publication: 2023 Nov 23 (Print Publication: 2024). |
DOI: | 10.1002/joa3.12958 |
Abstrakt: | This electrophysiology tracing demonstrates a graded postexcitation response of the retrograde limb of an orthodromic reentrant tachycardia circuit with varying His refractory VPB coupling intervals, which reiterates the decrementally conducting retrograde limb of the tachycardia circuit. Competing Interests: Authors declare no conflict of interests for this article. (© 2023 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society.) |
Databáze: | MEDLINE |