Usefulness of bougie-preloaded proseal laryngeal mask airway versus digital insertion technique in correct placement of the device.

Autor: Mathew J; Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India., Rajan S; Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India., Babu KC; Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India., Manoharan KS; Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India., Paul J; Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India., Kumar L; Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India.
Jazyk: angličtina
Zdroj: Journal of anaesthesiology, clinical pharmacology [J Anaesthesiol Clin Pharmacol] 2023 Oct-Dec; Vol. 39 (4), pp. 565-570. Date of Electronic Publication: 2023 Feb 02.
DOI: 10.4103/joacp.joacp_72_22
Abstrakt: Background and Aims: Digital technique of proseal laryngeal mask airway (PLMA) insertion carries high chance of failed first attempt successful placement. We aimed to compare the number of attempts taken for correct placement of bougie-preloaded PLMA versus traditional digital insertion technique. Ease of insertion, time taken, hemodynamic responses during insertion, and evidence of trauma were also assessed.
Material and Methods: This prospective, randomized, open-label study was performed in 60 patients. All patients were administered general anesthesia according to a standardized protocol.After induction of general anesthesia in group P, proseal insertion was performed following the traditional digital technique. In group B, bougie-preloaded PLMA was used. A soft gum elastic bougie was passed through the gastric channel of PLMA, with 15cm protruding distally through the gastric port. Attempts at successful insertion and ease of insertion were noted.
Results: Time taken for successful insertion was significantly shorter in group B compared to group P (15.3 ± 4.5 vs. 57 ± 12.02 s, respectively). The first attempt success in group B was 90% versus 60% in group P. The number of moderate to hard insertion was significantly lesser in group B (10 vs. 40, respectively). Blood stain on device was seen in 3.3% in group B compared to 30% in group P. MAP at insertion and at 1, 3, and 5 min was significantly higher in group P. Heart rates were comparable.
Conclusion: Bougie-preloaded proseal insertion has significantly higher first attempt insertion success rates and is significantly faster and less traumatic with blunted blood pressure response compared to traditional digital insertion technique.
Competing Interests: There are no conflicts of interest.
(Copyright: © 2023 Journal of Anaesthesiology Clinical Pharmacology.)