User Perceptions of Visual Clot in a High-Fidelity Simulation Study: Mixed Qualitative-Quantitative Study.

Autor: Gasciauskaite G; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Castellucci C; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Malorgio A; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Budowski AD; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Schweiger G; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Kolbe M; Simulation Centre, University Hospital Zurich, Zurich, Switzerland., Fries D; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Grande B; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Nöthiger CB; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Spahn DR; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Roche TR; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Tscholl DW; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland., Akbas S; Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland.
Jazyk: angličtina
Zdroj: JMIR human factors [JMIR Hum Factors] 2024 Jan 11; Vol. 11, pp. e47991. Date of Electronic Publication: 2024 Jan 11.
DOI: 10.2196/47991
Abstrakt: Background: Viscoelastic hemostatic assays, such as rotational thromboelastometry (ROTEM) or thromboelastography, enable prompt diagnosis and accelerate targeted treatment. However, the complex interpretation of the results remains challenging. Visual Clot-a situation awareness-based visualization technology-was developed to assist clinicians in interpreting viscoelastic tests.
Objective: Following a previous high-fidelity simulation study, we analyzed users' perceptions of the technology, to identify its strengths and limitations from clinicians' perspectives.
Methods: This is a mixed qualitative-quantitative study consisting of interviews and a survey. After solving coagulation scenarios using Visual Clot in high-fidelity simulations, we interviewed anesthesia personnel about the perceived advantages and disadvantages of the new tool. We used a template approach to identify dominant themes in interview responses. From these themes, we defined 5 statements, which were then rated on Likert scales in a questionnaire.
Results: We interviewed 77 participants and 23 completed the survey. We identified 9 frequently mentioned topics by analyzing the interview responses. The most common themes were "positive design features," "intuitive and easy to learn," and "lack of a quantitative component." In the survey, 21 respondents agreed that Visual Clot is easy to learn and 16 respondents stated that a combination of Visual Clot and ROTEM would help them manage complex hemostatic situations.
Conclusions: A group of anesthesia care providers found Visual Clot well-designed, intuitive, and easy to learn. Participants highlighted its usefulness in emergencies, especially for clinicians inexperienced in coagulation management. However, the lack of quantitative information is an area for improvement.
(©Greta Gasciauskaite, Clara Castellucci, Amos Malorgio, Alexandra D Budowski, Giovanna Schweiger, Michaela Kolbe, Daniel Fries, Bastian Grande, Christoph B Nöthiger, Donat R Spahn, Tadzio R Roche, David W Tscholl, Samira Akbas. Originally published in JMIR Human Factors (https://humanfactors.jmir.org), 11.01.2024.)
Databáze: MEDLINE