Virtual non-contrast series of photon-counting detector computed tomography angiography for aortic valve calcium scoring.
Autor: | Risch F; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany., Harmel E; Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany., Rippel K; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany., Wein B; Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany., Raake P; Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany., Girdauskas E; Department of Cardiac Surgery, University Hospital Augsburg, Augsburg, Germany., Elvinger S; Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany., Owais T; Department of Cardiac Surgery, University Hospital Augsburg, Augsburg, Germany., Scheurig-Muenkler C; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany., Kroencke T; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany. Thomas.Kroencke@uk-augsburg.de.; Centre for Advanced Analytics and Predictive Sciences, Augsburg University, Augsburg, Germany. Thomas.Kroencke@uk-augsburg.de., Schwarz F; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany.; Clinic for Diagnostic and Interventional Radiology, Donau-Isar-Klinikum, Deggendorf, Germany., Braun F; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany., Decker JA; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany. |
---|---|
Jazyk: | angličtina |
Zdroj: | The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2024 Apr; Vol. 40 (4), pp. 723-732. Date of Electronic Publication: 2024 Jan 04. |
DOI: | 10.1007/s10554-023-03040-4 |
Abstrakt: | The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNC (© 2024. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: |